RF Monolithics, Inc.
RFM Europe
2001 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
Phone: (972) 233-2903
Phone: 44 1963 251383
Fax: (972) 387-9148
Fax: 44 1963 251510
E-mail: info@rfm.com
http://www.rfm.com
SF1059A-111504
Page 1 of 2
Electrical Characteristics
Characteristic
Sym
f
C
IL
BW
3
Notes
1
Min
Typ
350.00
Max
Units
MHz
dB
kHz
dB
P-P
ns
P-P
Nominal Center Frequency
Passband
Insertion Loss at fc
3 dB Passband
8
10.0
1, 2
±400
±600
0.5
Amplitude Variation over fc ±250 kHz
Group Delay Variation over fc ±400 kHz
1.0
GDV
200
40
45
50
250
Rejection
fc-8.0 to fc-2.0 and fc+2.0 to +8.0 MHz
1, 2, 3
35
40
dB
fc-50 to fc-8.0 and fc+8.0 to fc+50 MHz
Ultimate
Operating Temperature Range
T
A
1
-20
+70
°C
Impedance Matching to 50
unbalanced
Case Style
Lid Symbolization (XX = 2 character date code)
External L-C
SM9171-10 9.1 x 7.1 mm Nominal Footprint
RFM SF1059A XX
SM9171-10
Designed for WLAN IF Applications
Low Insertion Loss
9.1 x 7.1 mm Version of SF1059A-1
Unbalanced Input and Output
Complies with Directive 2002/95/EC (RoHS)
Absolute Maximum Ratings
Rating
Value
+10
30
-40 to +85
Units
dBm
VDC
°C
Maximum Incident Power in Passband
Max. DC voltage between any 2 terminals
Storage Temperature Range
Suitable for lead-free soldering - Max Soldering Profile
260°C for 30 s
350.0 MHz
SAW Filter
SF1059A
Notes:
1.
Unless noted otherwise, all specitication apply over the operating temperature range with filter soldered to the specified demonstration board with
impedanced matching to 50
network analyzer.
Unless noted otherwise, all frequency specitications are referenced to the nominal center frequency, fc.
Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in final user application is dependent on PCB layout
and external impedance matching design. See Application Note No. 42 for details.
“LRIP” or “L” after the part number indicates “low rate initial production” and “ENG” or “E” indicates “engineering prototypes.”
The design, manufacturing process, and specifications of this filter are subject to change.
Either Port 1 or Port 2 may be used for either input or output in the design. However, impedances and impedance matching may vary between Port
1 and Port 2, so that the filter must always be installed in one direction per the circuit design.
US and international patents may apply.
RFM, stylized RFM logo, and RF Monolithics, Inc. are registered trademarks of RF Monolithics, Inc.
Electrostatic Sensitive Device. Observe precautions for handling.
2.
3.
4.
5.
6.
7.
8.
9.
Connection
Input or Return
Return or Input
Output or Return
Return or Output
Ground
Terminals
5
6
10
1
All others
Return is ground
Return is hot
Port 1
Port 2
Single Ended Operation
Differential Operation
Electrical Connections