RF Monolithics, Inc.
RFM Europe
2001 by RF Monolithics, Inc. The stylized RFM logo are registered trademarks of RF Monolithics, Inc.
Phone: (972) 233-2903
Phone: 44 1963 251383
Fax: (972) 387-8148
Fax: 44 1963 251510
E-mail: info@rfm.com
http://www.rfm.com
SF1126A-121604
Page 1 of 2
Electrical Characteristics
Characteristic
Sym
f
C
IL
BW
1.3
GDV
Notes
1
Min
Typ
Max
Units
MHz
dB
MHz
ns
P-P
°
P-P
Nominal Center Frequency
Passband
127.000
14
Insertion Loss at fc
1.3 db Passband
15.0
1, 2
±15.0
Group Delay Variation over fc ±fc12.0 MHz
Phase Linearity over fc±12.0 MHz
11
30
10
Rejection
< 107.0 MHz
> 147.25 MHz
Ultimate
1, 2, 3
40
40
dB
40
Operating Temperature Range
Frequency Temperature Coefficient
T
A
FTC
1
+25
+30
°C
-94
ppm/°C
Designed for Interactive Video Applications
Wide Bandwidth and Excellent GD Variation
9.1 x 7.1 mm Surface-mount Case
Single Ended Input and Output
Complies with Directive 2002/95/EC (RoHS)
Absolute Maximum Ratings
Rating
Value
+10
30
-40 to +85
Units
dBm
VDC
°C
Maximum Incident Power in Passband
Max. DC voltage between any 2 terminals
Storage Temperature Range
Suitable for lead-free soldering - Max. Soldering Profile
260°C for 30 s
127 MHz
SAW Filter
SF1126A
Notes:
1.
Unless noted otherwise, all specifications apply over the operating temperature range
with filter soldered to the specified demonstration board with impedance matching to 50
and measured with 50
network analyzer.
Unless noted otherwise, all frequency specifications are referenced to the nominal center
frequency, fc.
Rejection is measured as attenuation below the minimum IL point in the passband.
Rejection in final user application is dependent on PCB layout and external impedance
matching design. See Application Note No. 42 for details.
Part to part absolute delay measurement records the absolute delay mean across 1 dB
passband.
"LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E"
indicates "engineering prototypes."
The design, manufacturing process, and specifications of this filter are subject to change.
Either Port 1 or Port 2 may be used for either input or output in the design. However,
impedances and impedance matching may vary between Port 1 and Port 2, so that the fil-
ter must always be installed in one direction per the circuit design.
US and international patents may apply.
Electrostatic Sensitive Device. Observe precautions for handling.
2.
3.
4.
5.
6.
7.
8.
9.
Connection
Port 1 Hot (Input)
Port 1 Gnd Return
Port 2 Hot (Output)
Port 2 Gnd Return
Case Ground
Terminals
1
10
6
5
All others
Electrical Connections
Impedance Matching to 50
Unbalanced
Case Style
Lid Symbolization (YY = year, WW = week)
External L-C
SM9171-10 9.1 x 7.1 mm Nominal Footprint
RFM SF1126A YYWW
SM9171-10
Pb