.050
REF
1.27
.440 11.18
REF
.249 6.32
REF
C5-A-DC
"A"
ISDF-XX-D
FIG 1
-S: SINGLE END
(SFSD-10-28-XX-XX.XX-S SHOWN)
C
+ .015[0.38] REF
(No OF POS x .050[1.27])
.080
REF
2.03
.120
REF
3.05
.145
REF
3.68
.250 6.35
REF
.050 1.27
REF
CL
02
01
N (SEE TABLE 2)
N-1 (SEE TABLE 2)
SFSDX-XX-XXX-XX-XX.XX-XX-XXX
No OF POSITIONS
-05, -07, -10, -15, -20, -25,
-30 -35 -40, -45, & -50 (PER ROW)
AVAILABLE AS STANDARD
-02 THRU -50 AVAILABLE AS ASO
WIRE GAUGE (AWG)
-28, -30
END OPTION
(END OPTION COMBINATIONS NOT AVAILABLE)
-NUS: NOTCH UP, STRAIGHT
(PIN 1 TO PIN N-1)
-NDS: NOTCH DOWN, STRAIGHT
(PIN 1 TO PIN 2)
-NUX: NOTCH UP, CROSSED
(PIN 1 TO PIN N)
-NDX: NOTCH DOWN, CROSSED
(PIN 1 TO PIN 1)
-NXX OPTION (END 2)
(ONLY AVAILABLE WITH -D, -DL, -DR)
SPECIFY IN INCHES
(SINGLE END: 03.00 INCH [76.2mm]
MINIMUM,
DOUBLE END: 03.25 INCH [82.6mm]
MINIMUM)
ASSEMBLED LENGTH
-S: SINGLE END
-D: DOUBLE END
(MUST CHOOSE FROM -NXX OPTIONS)
-SL: SINGLE ENDED WITH FRICTION LOCK
(SEE SHEET 2, FIG 3) (ONLY AVAILABLE
ON -10 THRU -50 POSITION)
-DL: DOUBLE ENDED WITH FRICTION LOCK
(SEE SHEET 2, FIG 4) (ONLY AVAILABLE
ON -10 THRU -50 POSITION)
(MUST CHOOSE FROM -NXX OPTIONS)
-SR: SINGLE ENDED WITH RETENTION LATCH
(SEE SHEET 3, FIG 5)(USE SUB-IM-LTC-07-01-N)
(ONLY AVAILABLE ON -02 THRU -50 POS)
-DR: DOUBLE ENDED WITH RETENTION LATCH
(SEE SHEET 3, FIG 6)(USE SUB-IM-LTC-07-01-N)
(ONLY AVAILABLE ON -02 THRU -50 POS)
(MUST CHOOSE FROM -NXX OPTIONS)
COLOR CODE:
LEAVE BLANK FOR ALL BLACK WIRE
C: COLOR CODED WIRE, SEE COLOR
SEQUENCE TABLE, SHEET 3
(NOT AVAILABLE WITH FEP OPTION)
(SEE NOTE 8)
ASSEMBLED LENGTH:
SECTION "A"-"A"
C
DWCX-XX-XX-300
XX.XX .125[3.18]
ASSEMBLED LENGTH:
FIG 2
-D: DOUBLE END
(SFSD-10-28-XX-XX.XX-D-NUS SHOWN)
(SAME AS FIG 1, UNLESS OTHERWISE STATED)
C
FEP CABLE OPTION
-T: FEP
(LEAVE BLANK FOR STANDARD PVC INSULATION)
C
AA
PLATING SPECIFICATION
(VALUES GIVEN ARE IN MICRO INCHES)
-H: HEAVY GOLD, 30 Au / 50 Ni MIN ON
CONTACT, 3 Au / 50 Ni MIN ON TAIL
-G: GOLD, 10 Au / 50 Ni MIN ON
CONTACT, 3 Au / 50 Ni MIN ON TAIL
-F: FLASH SELECTIVE, 3 Au / 50 Ni MIN ON
CONTACT, 3 Au / 50 Ni MIN ON TAIL
-GF: FLASH SELECTIVE, 3 Au / 50 Ni MIN ON
CONTACT, 3 Au / 50 Ni MIN ON TAIL
(ONLY AVAILABLE TO EXISTING
CUSTOMERS; SEE -F PLATING)
(SEE TABLE 3, SHEET 1)
DO NOT
SCALE FROM
THIS PRINT
SHEET OF
UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE IN INCHES.
TOLERANCES ARE:
DECIMALS
ANGLES
.XX: .01 [.3]
2
.XXX: .005 [.13]
.XXXX: .0020 [.051]
MATERIAL:
.050[1.27] SOCKET DISCRETE CABLE ASSEMBLY
BY:
SFSDX-XX-XXX-XX-XX.XX-XX-XXX
DWG. NO.
DESCRIPTION:
PROPRIETARY NOTE
THIS DOCUMENT CONTAINS INFORMATION
CONFIDENTIAL AND PROPRIETARY TO
SAMTEC, INC. AND SHALL NOT BE REPRODUCED
OR TRANSFERRED TO OTHER DOCUMENTS OR
DISCLOSED TO OTHERS OR USED FOR ANY
PURPOSE OTHER THAN THAT WHICH IT WAS
OBTAINED WITHOUT THE EXPRESSED WRITTEN
CONSENT OF SAMTEC, INC.
DO NOT SCALE DRAWING
BRATCHER 5/5/2005
3
1
SHEET SCALE: 2:1
F:\DWG\MISC\MKTG\SFSDX-XX-XXX-XX-XX.XX-XX-XXX-MKT.SLDDRW
NOTES:
1.
REPRESENTS A CRITICAL DIMENSION.
2. MINIMUM PULLOUT FORCE: 3.0 LBS [13.3 N].
3. CONTACT MUST BE INSERTED UNTIL
RETENTION FEATURE LOCKS INTO PLACE.
4. ALL FINISHED GOODS ARE TO BE ELECTICAL
TESTED INCLUDING HI-POT TEST AT 1000 VOLTS DC.
AFTER FINAL ELECTRICALTEST, LABEL EACH ASSEMBLY
WITH 1 LABEL-ET.
5. TINNED COPPER WIRE IS RoHS COMPLIANT.
6. PARTS TO BE LAYER PACKAGED.
7. END OF DISCRETE WIRE MUST BE IN THE RANGE AFTER CRIMP.
8. FOR LENGTHS LESS THAN 12 in, TOLERANCE SHALL BE +/-.125.
FOR OTHER LENGTHS, TOLERANCE SHALL BE +/-2%.
9. NOTE DELETED.
10. REFER TO CRIMP SPECIFICATIONS PRINT FOR CRIMP AND STRIP
DIMENSIONS, TOLERANCES, AND TOOLING.
11. 3LB MIN WIRE CRIMP STRENGTH FOR -30 AWG AND
4.5LB MIN WIRE CRIMP STRENGTH FOR -28 AWG.
520 PARK EAST BLVD, NEW ALBANY, IN 47150
PHONE: 812-944-6733
FAX: 812-948-5047
e-Mail info@SAMTEC.com
code 55322
INSULATOR: LCP, COLOR: BLACK
CONTACT: BeCu
CABLE INSULATION: PVC OR FEP, SEE CALLOUT
WIRE: DWC: TINNED COPPER. DWCT: SILVER
PLATED COPPER
(SEE TABLE 1)
REVISION AA