tfs110F.doc
VI TELEFILTER
vesion1.3
31.10.00
Filter specification
TFS 110 F - 1/4
____________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Vectron International Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
Measurement condition
Ambient temperature:
Input power level:
Terminating impedances
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 110 F is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The reference frequency fc is the arithmetic mean value of the upper and lower frequencies at
the 30 dB filter attenuation level relative to the insertion loss ae.
D a t a
____________________________________________________________________________________________________
Insertion loss
ae = amin
(reference level)
____________________________________________________________________________________________________
Reference frequency
______________________________________________________110,592 MHz
Pass band shape
____________________________________________________________________________________________________
3 dB bandwidth
BW
10 dB bandwidth
20 dB bandwidth
30 dB bandwidth
40 dB bandwidth
____________________________________________________________________________________________________
Relative attenuation
arel
fc + 475
kHz
fc - 425
kHz
fc ± 800
kHz
fc + 1200
kHz
fc - 1210
kHz
fc + 1375
kHz
fc - 1395
kHz
fc + 1500
kHz ... fc + 10
MHz
kHz ... fc - 10
MHz
fc - 1535
Group delay
GD
Ripple fc ± 800 kHz
Temperature coefficient
TC 1st order
)
)
____________________________________________________________________________________________________
Frequency inversion temperature
____________________________________________________________________________________________________
Operating temperature range
Storage temperature range
____________________________________________________________________________________________________
Input power level
____________________________________________________________________________________________________
Permissible DC voltage
VDC
Permissible AC voltage
____________________________________________________________________________________________________
Generated:
Checked / approved:
23° C
0 dBm
for input: 890
||
- 5,6 pF
for output:
680
||
- 5,9 pF
typ. value
tolerance / limit
11,9 dB
14
dB
± 60
kHz
Gaussian
-
965
1695
2255
2600
kHz
kHz
kHz
kHz
-
-
-
-
-
-
-
-
-
-
-
-
dB
dB
≤
3
≤
3
≤
10
≥
20
≥
20
≥
30
≥
30
≥
40
≥
40
dB
dB
dB
dB
dB
dB
dB
dB
dB
> 45
> 45
150
ns
max 300
ns
+ 1,7
- 0,06
ppm/K
ppm/K2
-
-
+ 10
°C
-
- 10 °C ... + 60 °C
- 40 °C ... + 85 °C
-
max. + 10
dBm
-
12
10
V
V