tfs 120C.doc
VI TELEFILTER
1. Measurement condition
Ambient temperature
T
A
:
Input power level:
Typical terminating impedances in
f
N
:
2. Characteristics
Remark:
Reference level for the relative attenuation
arel
of the
TFS 120C
is the minimum of the pass band attenuation
amin.
The minimum of the
pass band attenuation
amin
is defined as the insertion loss
ae
. The nominal frequence
f
N
is fixed at
120,0 MHz
without tolerance or limit.
The reference frequence
fc
is the arithmetic mean value of the upper and lower frequencies at the
40 dB
filter attenuation level relative to the
insertion loss
ae
. The temperature coefficient of frequency
Tc
f
is valid both for the reference frequency
fc
and the frequency response of the
filter in the operating temperature range.
Data
Insertion loss
(Reference level)
ae
Nominal frequency
f
N
Centre frequency
fc
at ambient temperature
( f
CAT
)
Pass band
Amplitude ripple (p-p):
f
N
... f
N
± 4,45 MHz
Amplitude ripple (p-p):
f
N
... f
N
± 4,50 MHz
Bandwidth
at ambient temperature
:
1,0 dB - band width
1,5 dB - band width
3 dB - band width
40 dB - band width
Relative attenuation
arel
f
N
f
N
± 4,5
MHz
f
N
± 5
MHz
f
N
± 25
MHz
f
N
- 120
MHz
f
N
- 25
MHz
f
N
+ 25
MHz
f
N
+ 300
MHz
Group delay
Group delay ripple in pass band (p-p):
Triple transit attenuation compared to main signal
Crosstalk
Frequency inversion temperature ( T
o
)
Temperature coefficient of frequency ( Tc
f
)
Frequency deviation of fc over temperature T : *)
Operating temperature range
Storage temperature range
Input power level
Permissible DC voltage
V
DC
Permissible DC voltage
V
pp
*) f
To
is reference frequence
fc
at frequency inversion temperature (
T
o
)
Generated:
Checked/Approved:
Version 1.0
TFS 120 C
31.10.00
1/4
Filter specification
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
____________________________________________________________________________________________________________________________________________________________________________________________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
Package, pin connection and 50
matching network
23 °C
0
dBm
for input:
1270
-11,7 pF.
for output:
4330
-2,9 pF.
(see sheet 2.)
typ. value
27 ± 0,5
-
120,01
tolerance / limit
dB
MHz
dB
MHz
max 33
120,0
-
f
N
- 4,5 MHz ... f
N
+ 4,5...MHz
0,6
dB
dB
-
max 3,0
8,98
9,07
9,15
9,90
MHz
MHz
MHz
MHz
dB
dB
dB
μs
ns
dB
dB
dB
dB
μs
ns
-
max 3
min 40
42...70
70
70
3,03
120
60
max 6
max 400
55...67
-5 °C
-0,036
ppm/K2
-
fc(Hz) = Tc
f
(ppm/K) x (T - T
o
)2 x f
To
(MHz)
-20 °C ... + 75 °C
- 40 °C ... + 85 °C
-
max. + 10
dBm
V
V
12
10
Wadim P. Dunzow
Dr. Bert Wall