File name: Tfs150N.doc
VI TELEFILTER
Version 3.2
TFS 150N
13.01.2003
1/5
Filter specification
1. Measurement condition
Ambient temperature
T
A
:
Input power level:
Terminating impedances at fc * ) :
2. Characteristics
Remark:
Reference level for the relative attenuation
arel
of the
TFS 150N
is the minimum of the pass band attenuation
amin
. The minimum of
the pass band attenuation amin is defined as the insertion loss
ae
. The reference frequency
fc
is the arithmetic mean value of the upper and lower
frequencies at the
3 dB
filter attenuation level relative to the insertion loss
ae
. The temperature coefficient of frequency
Tc
f
is valid both for the
reference frequency
fc
and the frequency response of the filter in the operating temperature range. The frequency shift of the filter in the operating
temperature range is not included in the production tolerance scheme.
D a t a
23 °C
0 dBm.
for input:
for output:
280
- 22,7 pF.
210
- 27,0 pF.
typ. value
tolerance / limit
Insertion loss
(reference level)
ae = amin
24,7
dB
max. 25
dB
Centre frequency
at ambient temperature T
A
fc
150,01
MHz
150,0 ± 0,1
MHz
Pass band
PB
4,50
MHz
f
C
... f
C
± 2,05
MHz
Pass band ripple ( p–p ) :
0,5
dB
max.
1
dB
Bandwidth
at ambient temperature T
A
1 dB
3 dB
4,62
4,77
MHz
MHz
min.
min.
4,1
4,6
MHz
MHz
25 dB
40 dB
45 dB
5,22
5,33
5,36
MHz
MHz
MHz
max.
max.
max.
5,3
6,0
6,4
MHz
MHz
MHz
Relative attenuation
arel
f
C
f
C
± 2,05 MHz ... f
C
±
... f
C
±
2,05 MHz
2,30 MHz
-
-
max.
max.
1
3
dB
dB
f
C
± 2,65 MHz ... f
C
±
f
C
± 3,0 MHz ... f
C
±
f
C
± 3,2 MHz ... f
C
± 100
3,0 MHz
3,2 MHz
-
dB
dB
min.
min.
min.
25
40
45
dB
dB
dB
46
MHz
50...70
Group delay ( mean value in PB )
Group delay ripple in PB:
Deviation from linear phase in PB (p-p):
3,92
μs
ns
degree
max.
max. 120
4,5
μs
ns
100
2,7
-
Input VSWR (S11) in PB :
Output VSWR (S22) in PB :
Triple transit attenuation compared to main signal
Crosstalk
15
15
50
dB
dB
dB
dB
-
-
-
-
60...70
Input power level
max. 20
dBm
Frequency inversion temperature ( T
)
Temperature coefficient of frequency ( Tc
f
)
Frequency deviation of fc over temperature:
** )
20
°C
ppm/K2
-
-
- 0,036
fc(Hz) = Tc
f
(ppm/K) x (T - T
o
)2 x f
O
(MHz)
Operating temperature range ( OTR )
Storage temperature range
-
-
- 33 °C ... + 85 °C
- 40 °C ... + 85 °C
*) The terminating impedances depend on parasitics and q-values of matching elements and the board used, and are to be understood as
reference values only. Should there be additional questions do not hesitate to ask for an application note or contact our design team.
**) f
O
= f
To
is reference frequency fc at frequency inversion temperature (T
o
)
generated:
W. Dunzow
checked / approved:
Dr. Bert Wall
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
E-Mail:
tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is assumed
as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.