Ltp: tft033
VI TELEFILTER
1. General
The filter is single ended driven. It is matched to 50
.
The matching element values given below are valid on the test PCB. If the parasitics
on the customer PCB and on this PCB are different, the matching elements have to
be optimized regarding the circuit and PCB design.
There are ground pin thru’s under the filter and in the other area of the PCB to
decrease cross talk.
The matching elements have been chosen from the E12- series (European standard
series with fixed tolerances) to get the best agreement between the PCB
measurement and the measurement in a reference test fixture.
2. Theoretical matching
The source and load impedances of the filter are:
source impedance:
1000
|| - 5.8 pF
load impedance:
1300
|| - 5.8 pF
The following theoretical matching circuit was calculated from these values:
LB-IN
version 1.3
13.10.00
Application Note
TFS 211 C- 1/2
______________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-0 / Fax: (+49) 3328 4784-30
598-0075
E-Mail: tft@telefilter.com
_______________________________________________________________________
_______________________________
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603)
E-Mail: vti@vtinh.com
SAW
1,2,3,6,7,8
4
9
L4
Output
50 Ohm
L6
L1
Input
50 Ohm
L3
5
10
L5
L2
50 Ohm:50 Ohm
LB-OUT
50 Ohm:50 Ohm
L1 = L2 = 82 nH
L3 = 230 nH (220 nH)
L4 = L5 = 100 nH
L6 = 200 nH (180nH)