Measurement condition
Package, pin connection and 50
matching network
Ambient temperature:
Input power level:
Terminating impedances
for input:
for output:
23
°
C
0 dBm
see sheet 2
960
|| -2 pF
960
|| -2 pF
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 82 A is the minimum of the pass band attenuation amin. The
minimum of the pass band attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean
value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion loss ae. The nominal
frequency fN is fixed on 82,8 MHz without tolerance. The given values for the relative attenuation arel and for the group delay
ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted due to the temperature
coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
D a t a
____________________________________________________________________________________________________
Insertion loss
ae = amin
(Reference level)
____________________________________________________________________________________________________
Nominal frequency
____________________________________________________________________________________________________
Centre frequency
____________________________________________________________________________________________________
Relative attenuation
arel
fN
±
12 kHz
fN
- 1000 kHz ...
fN
-
400 kHz
fN
-
400 kHz ...
fN
-
200 kHz
fN
-
200 kHz ...
fN
-
120 kHz
fN
-
120 kHz ...
fN
-
60 kHz
fN
+
60 kHz ...
fN
+ 120 kHz
fN
+ 120 kHz ...
fN
+ 500 kHz
+ 500 kHz ...
+1000 kHz
____________________________________________________________________________________________________
Group delay distortion
GDD
±
8 kHz
____________________________________________________________________________________________________
Operating temperature range
Storage temperature range
____________________________________________________________________________________________________
Temperature coefficient of frequency
___________________________________TCf
Frequency inversion temperature
____________________________________________________________________________________________________
Permissible DC voltage
____________________________________________________________________________________________________
typ. value
tolerance / limit
-
max 4
dB
-
82,8
MHz
82,8
MHz
-
max. 3
min. 60
min. 50
min. 40
min. 20
min. 20
min. 39
dB
dB
dB
dB
dB
dB
dB
-
-
-
-
-
-
-
-
max. 10
s
- 30 °C ... + 60 °C
- 40 °C ... + 85 °C
ca. - 0,036 ppm/K2
+ 20
°C
-
-
max. 10
V
Generated:
Checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
Vectron Technologies, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com