______________________________________________________________________________________________________
______________________________________________________________________________________________________
______________________________________________________________________________________________________
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
Measurement condition
Ambient temperature:
23
°
Generated:
Checked / approved:
0 dBm
850
II -2 pF
850
II -2 pF
Input power level:
Source impedance:
Load impedance:
Construction and pin configuration
see page 2
Characteristics
Remark:
Reference level for the relative attenuation arel of the TFS 86 A is the minimum of the pass band attenuation amin. The minimum of the pass band
attenuation amin is defined as the insertion loss ae. The centre frequency fo is the arithmetic mean value of the upper and lower frequencies at the
3dB filter attenuation level relative to the insertion loss ae. The nominal frequency fN is fixed on 86,85 MHz without tolerance. The given values for
the relative attenuation arel and for the group delay ripple have to be reached at the frequencies given below also if the centre frequency fo is shifted
due to the temperature coefficient of frequency TCf in the operating temperature range and due to a production tolerance for the centre frequency fo.
D a t a
______________________________________________________________________________________________________
Insertion loss
ae = amin
(Reference level)
______________________________________________________________________________________________________
Nominal frequency
______________________________________________________________________________________________________
Centre frequency
______________________________________________________________________________________________________
Pass band ripple
±
13 kHz
______________________________________________________________________________________________________
Relative attenuation
arel
fN
±
15 kHz
fN
- 1000 kHz ...
fN
-
940 kHz
fN
-
940 kHz ...
fN
-
880 kHz
fN
-
880 kHz ...
fN
-
400 kHz
fN
-
400 kHz ...
fN
- -120 kHz
fN
-
120 kHz ...
fN
-
60 kHz
fN
+
60 kHz ...
fN
+ 120 kHz
fN
+ 120 kHz ...
fN
+ 150 kHz
fN
+ 150 kHz ...
fN
+ 400 kHz
+ 400 kHz ...
+1000 kHz
______________________________________________________________________________________________________
Group delay distortion
GDD
±
11 kHz
______________________________________________________________________________________________________
Intermodulation
Intermodulation in the composite signal by
± 60 kHz and
± 120 kHz each of -20 dBm
______________________________________________________________________________________________________
Operating temperature range
Storage temperature range
______________________________________________________________________________________________________
Temperature coefficient of frequency
______________________________________________________________________________________________________
Frequency inversion temperature
______________________________________________________________________________________________________
Permissible DC voltage
______________________________________________________________________________________________________
typ. value
tolerance / limit
-
max 4
dB
-
86,85
MHz
86,85
MHz
-
-
max. 1,5
dB
max. 3
min. 50
min. 70
min. 50
min. 40
min. 20
min. 20
min. 40
min. 30
dB
dB
dB
dB
dB
dB
dB
dB
dB
-
-
-
-
-
-
-
-
-
-
max. 10
s
-
max. -90
dBm
- 20 °C ... + 70 °C
- 40 °C ... + 85 °C
ca. - 0,036 ppm/K2
+ 20 °C ... + 30 °C
-
max. 10
V