欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: TLC2552CDGKR
廠商: TEXAS INSTRUMENTS INC
元件分類: ADC
英文描述: 2-CH 12-BIT SUCCESSIVE APPROXIMATION ADC, SERIAL ACCESS, PDSO8
封裝: GREEN, PLASTIC, MSOP-8
文件頁數: 21/27頁
文件大小: 667K
代理商: TLC2552CDGKR
TLC2551, TLC2552, TLC2555
5-V, LOW-POWER, 12-BIT, 175/360 KSPS,
SERIAL ANALOG-TO-DIGITAL CONVERTERS WITH AUTOPOWER DOWN
SLAS276D – MARCH 2000 – REVISED MAY 2003
3
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
Terminal Functions
TLC2551
TERMINAL
I/O
DESCRIPTION
NAME
NO.
I/O
DESCRIPTION
AIN
4
I
Analog input channel
CS
1
I
Chip select. A high-to-low transition on the CS input removes SDO from 3-state within a maximum setup time.
CS can be used as the FS pin when a dedicated DSP serial port is used.
FS
7
I
DSP frame sync input. Indication of the start of a serial data frame. Tie this terminal to VDD if not used.
GND
3
I
Ground return for the internal circuitry. Unless otherwise noted, all voltage measurements are with respect to GND.
SCLK
5
I
Output serial clock. This terminal receives the serial SCLK from the host processor.
SDO
8
O
The 3-state serial output for the A/D conversion result. SDO is kept in the high-impedance state until CS falling edge
or FS rising edge, whichever occurs first. The output format is MSB first.
When FS is not used (FS = 1 at the falling edge of CS), the MSB is presented to the SDO pin after CS falling edge
and output data is valid on the first falling edge of SCLK.
When CS and FS are both used (FS = 0 at the falling edge of CS), the MSB is presented to the SDO pin after the
falling edge of CS. When CS is tied/held low, the MSB is presented on SDO after rising FS. Output data is valid on
the first falling edge of SCLK. (This is typically used with an active FS from a DSP.)
VDD
6
I
Positive supply voltage
VREF
2
I
External reference input
TLC2552/55
TERMINAL
I/O
DESCRIPTION
NAME
NO.
I/O
DESCRIPTION
AIN0 /AIN(+)
4
I
Analog input channel 0 for TLC2552—Positive input for TLC2555
AIN1/AIN (–)
5
I
Analog input channel 1 for TLC2552—Inverted input for TLC2555
CS
1
I
Chip select. A high-to-low transition on CS removes SDO from 3-state within a maximum delay time. This pin can
be connected to the FS output from a DSP on a dedicated serial port.
GND
3
I
Ground return for the internal circuitry. Unless otherwise noted, all voltage measurements are with respect to GND.
SCLK
7
I
Output serial clock. This terminal receives the serial SCLK from the host processor.
SDO
8
O
The 3-state serial output for the A/D conversion result. SDO is kept in the high-impedance state when CS is high
and presents output data after the CS falling edge until the LSB is presented. The output format is MSB first. SDO
returns to the Hi-Z state after the 16th SCLK. Output data is valid on the falling SCLK edge.
VDD
6
I
Positive supply voltage
VREF
2
I
External reference input
detailed description
The TLC2551, TLC2552, and TLC2555 are successive approximation (SAR) ADCs utilizing a charge
redistribution DAC. Figure 1 shows a simplified version of the ADC.
The sampling capacitor acquires the signal on AIN during the sampling period. When the conversion process
starts, the SAR control logic and charge redistribution DAC are used to add and subtract fixed amounts of charge
from the sampling capacitor to bring the comparator into a balanced condition. When the comparator is
balanced, the conversion is complete and the ADC output code is generated.
相關PDF資料
PDF描述
TLC2555CDGKR 1-CH 12-BIT SUCCESSIVE APPROXIMATION ADC, SERIAL ACCESS, PDSO8
TLC2555IDGKR 1-CH 12-BIT SUCCESSIVE APPROXIMATION ADC, SERIAL ACCESS, PDSO8
TLC2552CDGKG4 2-CH 12-BIT SUCCESSIVE APPROXIMATION ADC, SERIAL ACCESS, PDSO8
TLC2555IDGKG4 1-CH 12-BIT SUCCESSIVE APPROXIMATION ADC, SERIAL ACCESS, PDSO8
TLC2552IDGKG4 2-CH 12-BIT SUCCESSIVE APPROXIMATION ADC, SERIAL ACCESS, PDSO8
相關代理商/技術參數
參數描述
TLC2552CDGKRG4 功能描述:模數轉換器 - ADC 12-Bit 400 kSPS Dual Ch Auto Sweep RoHS:否 制造商:Texas Instruments 通道數量:2 結構:Sigma-Delta 轉換速率:125 SPs to 8 KSPs 分辨率:24 bit 輸入類型:Differential 信噪比:107 dB 接口類型:SPI 工作電源電壓:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作溫度:+ 85 C 安裝風格:SMD/SMT 封裝 / 箱體:VQFN-32
TLC2552EVM 功能描述:數據轉換 IC 開發工具 TLC2552 Eval Mod RoHS:否 制造商:Texas Instruments 產品:Demonstration Kits 類型:ADC 工具用于評估:ADS130E08 接口類型:SPI 工作電源電壓:- 6 V to + 6 V
TLC2552ID 功能描述:模數轉換器 - ADC 12bit SAR ADC RoHS:否 制造商:Texas Instruments 通道數量:2 結構:Sigma-Delta 轉換速率:125 SPs to 8 KSPs 分辨率:24 bit 輸入類型:Differential 信噪比:107 dB 接口類型:SPI 工作電源電壓:1.7 V to 3.6 V, 2.7 V to 5.25 V 最大工作溫度:+ 85 C 安裝風格:SMD/SMT 封裝 / 箱體:VQFN-32