Vectron International
267 Lowell Road, Hudson, NH 03051
Tel: 1-88-VECTRON-1
Web: www.vectron.com
103
Clock and Data Recovery Products
TRU-600
Features:
Output jitter typical 10 ps rms
Low-cost modular solution
Choice of data rates form
124.416 Mb/s to 622.08 Mb/s
SONET/SDH compatible
100K ECL/PECL compatible
inputs and outputs
Low power consumption
Quartz SAW filter technology
External Clock Enable for LOS
Normal Clock Frequency
1
Supply Current
Supply Voltage
Data Input Voltage Low
Data Input Voltage High
Data/Clock Output Voltage Low2
Input Clock/Frequency Deviation
3
Clock/Data Alignment
4
Data/Clock Output Rise Time
5
Data/Clock Output Fall Time
5
Output Clock Duty Cycle
f
o
I
EE
V
CC
V
IL
V
IH
V
OL
D
C
T
CDA
T
TLH
T
THS
-
124.416
50
4.5
-1.81
-1.17
-1.95
-200
-100
275
275
45
-
622.08
75
5.5
-1.48
-0.88
-1.63
200
100
575
575
55
MHz
mA
V
V
V
V
ppm
ps
ps
ps
%
μ
s
ps rms
mW
°
C
°
C/s
V
65
5
-
-
-
-
-
375
375
-
Acquisition Time
6
T
A
J
C
P
d
T
stg
T
LS
-
-
-
-
2
-
-
Output Clock Random Jitter
7
Power Consumption
Storage Temperature
Soldering Temperature/Duration
10
325
-55
-
0
125
240/10
8.0
Supply Voltage
V
CC
-V
EE
1. The TRU-600 meets all SONET.SDH requirements for jitter transfer and jitter tolerance mask characteristics at the stan-
dard SONET transmission rates.
2. Measured with respect to Vcc with load R
L
of 50 ohms to Vcc-2v. ECL voltage levels are specified for dc measurement.
An additional tolerance of 50 mV should be added for dynamic measurement.
3. Allowable input clock frequency variation with respect to the nominal clock frequency (F
N
) over the entire operating
temperature range.
4. Alignment of clock and data outputs.
5. Measured at 20% to 80% levels.
6. Time required to achieve valid data and clock outputs with an input transition density of at least 50%.
7. Measured with an input data pseudorandom word (PRW) 2
23
-1.
Performance Characteristics
Parameter
Description:
The TRU-600 is a high frequency, SAW based Clock and Data
Recovery Module. It offers very low jitter outputs, excellent stability
and fast acquisition time.
Symbol
Min.
Typical
Max
Unit
Consult website for additional information
.
CDR