F A C T O R Y A U T O M A T I O N
24
Subject to reasonable modifications due to technical advances.
Pepperl+Fuchs Group · Tel.: Germany (6 21) 7 76-11 11 · USA (3 30) 4 25 35 55 · Singapore 7 79 90 91 · Internet http://www.pepperl-fuchs.com
Copyright by Pepperl+Fuchs, Printed in Germany
5)
to IEC 68-2-6 and IEC 68-2-27
Synchronisation:
In order to suppress mutual interference, the
sensor operates via one sychronised input. If
the input is unswitched, the senor operates
at an internally generated pulse rate. The
sensor can be synchronised by the super
position of the square - shaped voltage. One
synchronising pulse at the synchronisation
input enables one measuring cycle to be
completed. The pulse width must be greater
than 100 μs. The measuring cycle com-
mences with the descending flank. The state
of the switching output changes after the
switching threshold has been exceeded five
times, as determined internally by five meas-
urements. A low level
≥
1 s, or an open
synchronisation input results in normal oper-
ation of the sensor. Synchronisation cannot
take place during teaching and vice versa.
Two operating modes are possible:
1. Multiple sensors are controlled with the
same synchronising signal. The sensors
operate on the same pulse.
2. The synchronising pulses are fed cyclical-
ly to only one sensor at a time. The sen-
sors operate in multiplex mode. A high
level at the sychronisation input deacti-
vates the sensor.
To set the Switch Points:
The ultrasonic sensor is provided with a
switching output with two teachable switch
points. These are set up by applying the
supply voltage -U
bzw. +U
to the teaching
input. The supply voltage should be applied
to the teaching input for at least 1 s. During
the teaching process the LED's indicate
whether the sensor has recognised the tar-
get. The switch points A1 and A2 are taught
by voltage -U
B
and + U
B,
, respectively.
Five functions can be set:
1. Window mode, normally open function
2. Window mode, normally closed function
3. One switch point, normally open function
4. One switch point, normaly closed function
5. Detection of presence of object
- Switch output
- 5 different output functions
available
- Teaching input
- Can be synchronised
- Can be deactivated
- Watchdog
Ultrasonic Sensors
Single Head System with one Switch Output
Figure 1
Housing material:
Nickel plated brass
Transducer material:
Epoxy resin/hollow glass sphere mixture
Polyurethane foam
Cover: PBT
(Polybutylenterephthalate)
M30x1.5
LED
94
22
wdthacrossfats36 thckness5
D
Detection range:
60 mm ... 500 mm
Figure 1
Version:
Transceiver with one switch output
Order code:
pnp
npn
UB 500-30GM-E2-V15
UB 500-30GM-E0-V15
Operating data:
Detecting range
Standart test plate
(min. flat surface)
Close range
(unsuitable for switching)
Aperture angle of sonic lobe
Transducer frequency
Response time
Switching hysteresis
Reproducibility
Temperature drift
Operating cycle frequency
Measuring cycle time t
Synchron. frequency equi-pulsed
≤
1 / t
m1
Synchron. frequency multiplex
60 mm ... 500 mm
100 mm x 100 mm
0 mm ... 60 mm
approx. 5
°
at -3 dB
approx. 375 kHz
approx. 38 ms
≤
1 % of the set operating distance
≤
1 %
0.2 % / K
max. 13 Hz
approx. 6.5 ms
≤
1 / t
m1
+ 1 / t
m2
+ ...
Electrical Data:
Operating voltage U
B
Ripple
Rated operating current
Switch output
pnp
npn
Teaching input
20 V DC ... 30 V DC
±
10 %
ss
, U
B
= 33 V
≤
60 mA
200 mA k , U
B
-3 V short circuit/overload resistent
E2
E0
-U
B
... (-U
+2 V) near switch point
(+U
-2 V) ... +U
far switch point
-U
B
... (-U
+1 V) Low level
(-U
+5 V) ... +U
High level
Input impedance 27 k
≥
100 μs
≥
100 μs
Synchronising input
Synchronisation pulse width
Synchronisation pause width
Indicators:
LED
green
LED
red
LED
yellow
"Power on", teaching function object detected
"Fault", object uncertain
Switching condition indicator, teaching function, no
object detected
Mechanical Data:
Operating temperature range
Storage temperature range
Protection class to DIN 40 050
Permissible shock and
vibration loading
5)
Connection type
248 Kelvin ... 343 Kelvin (-25
°
C ... +70
°
C)
233 Kelvin ... 358 Kelvin (-40
°
C ... +85
°
C)
IP 65
b
≤
30 g, T
≤
11 ms
f
≤
55 Hz, a
≤
1 mm
Equipment connector - V15
in compliance with
EN 60974-5-2