Total Power
Part No.
Dimensions
Single Outputs:
50-200W
VI-LC
–
8.6" x 2.5" x 0.99"
(218,4 x 63,5 x 25,2mm)
100-400W
VI-MC
–
8.6" x 4.9" x 0.99"
(218,4 x 124,5 x 25,2mm)
300-600W
VI-NC
–
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Dual Outputs:
100-400W
VI-PC
–
8.6" x 4.9" x 0.99"
(218,4 x 124,5 x 25,2mm)
150-600W
VI-QC
–
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Triple Outputs:
150-600W
VI-RC
–
8.6" x 7.3" x 0.99"
(218,4 x 185,4 x 25,2mm)
Product Highlights
ComPAC delivers up to 600W from
one, two, or three outputs in a package
just 0.99” (25,2mm) in height with the
field proven performance, high
efficiency and high reliability inherent
in Vicor’s component level power
converters. ComPAC meets British
Telecom and European norms for input
surge withstand and meets conducted
emissions of EN55022 Class B.
ComPAC is offered with input voltage
ranges optimized for industrial and
telecommunication applications and
provides extended input overvoltage
capability, input reverse polarity
protection, undervoltage lockout, and
master disable.
Features
Inputs 24, 48, and 300Vdc
Any output: 1 to 95Vdc
Input surge withstand:
British TelecomBTR 2511,
EN-61000-4-5
Meets British TelecomBTR 2511,
EN55022 Class B conducted emssions
UL, CSA, TüV (IEC 950)
CE marked
80-90% efficiency
Up to 10W/cubic inch
Reverse polarity protected
Master disable
Overvoltage shutdown
DC-DC Switchers
50 to 600W
1-3 Outputs
Input Voltage
Nominal
1 = 24V
W = 24V
3 = 48V
N = 48V
6 = 300V 200 - 400V (2)
Range
21 - 32V (1)
18 - 36V (1)
42 - 60V (2)
36 - 76V (2)
Output Voltage
Z 2V
Y 3.3V
0 5V
X 5.2V
W5.5V
V 5.8V
T 6.5V
R 7.5V
M10V
1 12V
P 13.8V H 52V
2 15V
N 18.5V D 85V
3 24V
L 28V
J 36V
K 40V
4 48V
F 72V
B 95V
Output Power/Current
V
≥
5V
W = 100W
V = 150W
U = 200W
S = 300W
Q = 400W
V
out
< 5V
20A
30A
40A
60A
80A
Output Power/Current
V
≥
5V
S = 300W
P = 450W
M = 600W
V
out
< 5V
60A
90A
120A
Product Grade
E = -10°C to +85°C
C = -25°C to +85°C
I = -40°C to +85°C
M = -55°C to +85°C
Output Power/Current
V
out
≥
5V
Y = 50W
X = 75W
W = 100W
V = 150W
U = 200W
V
out
< 5V
10A
15A
20A
30A
40A
ComPAC Configuration Chart
Use the configuration chart at the right to define your
Vicor part number(s).
C omP A C
Max
output for
(1)
(2)
≥
5V
Outputs
150W
200W
<5V
Outputs
30A
40A
Conduction Cooled Models Available
Add "-CC" to the end of the part number.
(Consult factory for details.)
Long Term Safe Operating Area Curves
(1% duty cycle max. Z
s
=0.5
;
for short duration transient capability refer to page 3.)
0.1 1 10ms 100 1000
800V
Normal Operating Area
I.S.W.
Full Load
300V Input
S.D.
R.E.
500V
400V
200V
500ms
276V
Normal Operating Area
FI.S.W.
0.1 1 10ms 100 1000
48V Wide Range Input
R.E.
76V
125V
36V
S.D.
S.D.
100V
500ms
0.1 1 10ms 100 1000
100V
Normal Operating Area
FI.S.W.
100V
Standard
Wide Range
24V Inputs
R.E.
32V
21V
36V
18V
S.D.
160V
0.1 1 10ms 100 1000
Normal Operating Area
I.S.W.
Full Load
48V Input
R.E.
S.D.
60V
100V
42V
I.S.W.:
Input surge withstand, no degradation of performance.
R.E.:
Ratings Exceeded
S.D.:
Shutdown
ComPAC 10/02 1 of 4