SCHRACK
General Purpose Relays
PCB Relays
Power PCB Relay RT1 bifurcated
n
1 pole 12/16A, 1 form C (CO) contact
n
Sensitive DC coil, 200 or 400mW
n
5kV/10mm coil-contact, reinforced insulation
n
Ambient temperature 85°C
Typical applications
Switching from dry circuit up to 16A, including arc-less switching, with
extra high reliability
Approvals
VDE REG.-Nr. 6106, UL E214025, cCSAus 14385
Technical data of approved types on request
Contact Data
Contact arrangement
Rated voltage
Max. switching voltage
Rated current
Limiting making current,max. 4s, df 10% 16A
Breaking capacity max.
Contact material
Contact style
Frequency of operation, with/without load
Operate/release time max.
Bounce time max., form A/form B
1 form C (CO)
1)
250VAC
400VAC
12A
2)
16A
16A
4000VA
AgNi90/10
3000VA
AgNi90/10
gold plated
twin (bifurcated) contact
360/36000h
-1
10/5ms
4/9ms
Contact ratings
Type
IEC 61810
RT31C
RTB7D
RTB7D
UL 508
RT31C
RT31C
RTB7D
RTB7D
Mechanical endurance
12A version
16A version
1) 1 form A (NO) contact available on request
2) Recommended for switching load range ≤5A
Contact
Load
Cycles
A (NO)
C (CO)
C (CO)
16A, 250VAC, resistive, 85°C
12A, 250VAC, resistive, 85°C
5A, 250VAC, resistive, 85°C
50x10
3
1x10
3
100x10
3
A (NO)
C (CO)
C (CO)
A (NO)
16A, 250VAC, general purpose, 85°C
16A, 250VAC, general purpose, 40°C
12A, 250VAC, general purpose, 40°C
5A, 250VAC, general purpose, 85°C
50x10
3
6x10
3
6x10
3
100x10
3
>30x10
6
operations
>10x10
6
operations
Coil Data
Coil voltage range
12A version
16A version
Operative range, IEC 61810
Coil insulation system according UL
5 to 60VDC
5 to 110VDC
2
class F
Coil versions, 16A version
Coil
Rated
code
voltage
VDC
005
006
012
024
048
060
110
110
3) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Coil versions, 12A version
Coil
Rated
Operate
code
voltage
voltage
VDC
VDC
005
5
3.5
006
6
4.2
012
12
8.4
024
24
16.8
048
48
33.6
060
60
42.0
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Operate
voltage
VDC
3.5
4.2
8.4
16.8
33.6
42.0
77.0
Release
voltage
VDC
0.5
0.6
1.2
2.4
4.8
6.0
11.0
Coil
Rated coil
power
mW
403
400
400
400
417
420
420
resistance
±10%
3)
62
90
360
1440
5520
8570
3)
28800
3)
5
6
12
24
48
60
Release
voltage
VDC
0.5
0.6
1.2
2.4
4.8
6.0
Coil
Rated coil
power
mW
200
190
210
190
220
210
resistance
±10%
125
190
690
2980
10470
16980
F0144-C
Z
V
b