參數資料
型號: AD7755AARS
廠商: ANALOG DEVICES INC
元件分類: 模擬信號調理
英文描述: Energy Metering IC with Pulse Output
中文描述: SPECIALTY ANALOG CIRCUIT, PDSO24
封裝: SSOP-24
文件頁數: 16/16頁
文件大?。?/td> 250K
代理商: AD7755AARS
REV. B
AD7755
–16–
C
P
24-Lead Plastic DIP
(N-24)
24
1
12
13
PIN 1
1.275 (32.30)
1.125 (28.60)
0.280 (7.11)
0.240 (6.10)
0.195 (4.95)
0.115 (2.93)
0.015 (0.381)
0.008 (0.204)
0.325 (8.25)
0.300 (7.62)
SEATING
PLANE
0.060 (1.52)
0.015 (0.38)
0.210
(5.33)
MAX
0.022 (0.558)
0.014 (0.356)
0.200 (5.05)
0.125 (3.18)
0.150
(3.81)
MIN
0.100
(2.54)
BSC
0.070 (1.77)
0.045 (1.15)
OUTLINE DIMENSIONS
Dimensions shown in inches and (mm).
24
1
13
12
0.328 (8.33)
0.318 (8.08)
0.311 (7.9)
0.301 (7.64)
0.212 (5.38)
0.205 (5.207)
PIN 1
SEATING
PLANE
0.07 (1.78)
0.066 (1.67)
0.008 (0.203)
0.002 (0.050)
0.0256
(0.65)
BSC
0.078 (1.98)
0.068 (1.73)
0.015 (0.38)
0.010 (0.25)
0.009 (0.229)
0.005 (0.127)
0.037 (0.94)
0.022 (0.559)
8
°
0
°
24-Lead Shrink Small Outline Package
(RS-24)
Table VI. F1 and F2 Frequency with Half-Scale AC Inputs
Frequency on F1 and F2–
CH1 and CH2 Half-Scale AC Inputs
S1
S0
F
1–4
1.7
3.4
6.8
13.6
0
0
1
1
0
1
0
1
0.085 Hz
0.17 Hz
0.34 Hz
0.68 Hz
When selecting a suitable F
1–4
frequency for a meter design, the
frequency output at I
MAX
(maximum load) with a meter con-
stant of 100 imp/kWhr should be compared with Column 4 of
Table VI. The frequency that is closest in Table VI will deter-
mine the best choice of frequency (F
1–4
). For example, if a meter
with a maximum current of 25 A is being designed, the out-
put frequency on F1 and F2 with a meter constant of 100 imp/
kWhr is 0.153 Hz at 25 A and 220 V (from Table V). Looking
at Table VI, the closest frequency to 0.153 Hz in column four is
0.17 Hz. Therefore F
2
(3.4 Hz—see Table II) is selected for this
design.
Frequency Outputs
Figure 1 shows a timing diagram for the various frequency out-
puts. The outputs F1 and F2 are the low frequency outputs that
can be used to directly drive a stepper motor or electromechani-
cal impulse counter. The F1 and F2 outputs provide two alter-
nating low going pulses. The pulsewidth (t
1
) is set at 275 ms and
the time between the falling edges of F1 and F2 (t
3
) is approxi-
mately half the period of F1 (t
2
). If however the period of F1
and F2 falls below 550 ms (1.81 Hz) the pulsewidth of F1 and
F2 is set to half of their period. The maximum output frequen-
cies for F1 and F2 are shown in Table III.
The high frequency CF output is intended to be used for com-
munications and calibration purposes. CF produces a 90 ms-
wide active high pulse (t
4
) at a frequency proportional to active
power. The CF output frequencies are given in Table IV. As in
the case of F1 and F2, if the period of CF (t
5
) falls below 180 ms,
the CF pulsewidth is set to half the period. For example, if the CF
frequency is 20 Hz, the CF pulsewidth is 25 ms.
NOTE: When the high frequency mode is selected, (i.e., SCF =
0, S1 = S0 = 1) the CF pulsewidth is fixed at 18
μ
s. Therefore t
4
will always be 18
μ
s, regardless of output frequency on CF.
NO LOAD THRESHOLD
The AD7755 also includes a “no load threshold” and “start-up
current” feature that will eliminate any creep effects in the
meter. The AD7755 is designed to issue a minimum output
frequency on all modes except when SCF = 0 and S1 = S0 = 1.
The no-load detection threshold is disabled on this output mode
to accommodate specialized application of the AD7755. Any
load generating a frequency lower than this minimum frequency
will not cause a pulse to be issued on F1, F2 or CF. The mini-
mum output frequency is given as 0.0014% of the full-scale
output frequency for each of the F
1–4
frequency selections—see
Table II. For example, an energy meter with a meter constant
of 100 imp/kWhr on F1, F2 using F
2
(3.4 Hz), the maximum
output frequency at F1 or F2 would be 0.0014% of 3.4 Hz or
4.76
×
10
–5
Hz. This would be 3.05
×
10
–3
Hz at CF (64
×
F1 Hz).
In this example the no-load threshold would be equivalent to
1.7 W of load or a start-up current of 8 mA at 220 V. Compar-
ing this value to the IEC1036 specification which states that the
meter must start up with a load equal to or less than 0.4% Ib.
For a 5A (Ib) meter 0.4% of Ib is equivalent to 20 mA.
相關PDF資料
PDF描述
AD7755ABRS Energy Metering IC with Pulse Output
AD7755AAN Energy Metering IC with Pulse Output
AD7760 2.5 MSPS, 20-Bit ADC
AD7760BCP 2.5 MSPS, 20-Bit ADC
AD7760BSV 2.5 MSPS, 20-Bit ADC
相關代理商/技術參數
參數描述
ad7755aarsrl 制造商:Rochester Electronics LLC 功能描述:ENERGY METERING IC WITH P - Tape and Reel 制造商:Analog Devices 功能描述:
AD7755ABRS 制造商:AD 制造商全稱:Analog Devices 功能描述:Energy Metering IC with Pulse Output
AD7755AN 制造商:Rochester Electronics LLC 功能描述:ENERGY METERING IC WITH P - Bulk
AD7755ARS 制造商:Rochester Electronics LLC 功能描述:- Bulk
AD7756AN 制造商:Rochester Electronics LLC 功能描述:- Bulk