REV. 0
ADM1030
–11–
asserted low. The behavior of the high limit and
THERM
limit
is as follows:
1. Whenever the temperature measured exceeds the high tem-
perature limit, the
INT
pin is asserted low.
2. If the temperature exceeds the
THERM
limit, the
THERM
output asserts low. This can be used to throttle the CPU
clock. If the
THERM
-to-Fan Enable bit (Bit 7 of THERM
behavior/revision register) is cleared to 0, the fan will not run
full-speed. The
THERM
limit may be programmed at a
lower temperature than the high temperature limit. This
allows the system to run in silent mode, where the CPU can
be throttled while the cooling fan is off. If the temperature
continues to increase, and exceeds the high temperature limit,
an
INT
is generated. Software may then decide whether the
fan should run to cool the CPU. This allows the system to
run in SILENT MODE.
3. If the
THERM
-to-Fan Enable bit is set to 1, the fan will run
full-speed whenever
THERM
is asserted low. In this case,
both throttling and active cooling take place. If the high
temperature limit is programmed to a lower value than the
THERM
limit, exceeding the high temperature limit will
assert
INT
low. Software could change the speed of the fan
depending on temperature readings. If the temperature con-
tinues to increase and exceeds the
THERM
limit,
THERM
asserts low to throttle the CPU and the fan runs full-speed.
This allows the system to run in PERFORMANCE MODE,
where active cooling takes place and the CPU is only throttled
at high temperature.
Using the high temperature limit and the
THERM
limit in this
way allows the user to gain maximum performance from the system
by only slowing it down, should it be at a critical temperature.
Although the ADM1030 does not have a dedicated Interrupt
Mask Register, clearing the appropriate enable bits in Configu-
ration Register 2 will clear the appropriate interrupts and mask
out future interrupts on that channel. Disabling interrupt bits
will prevent out-of-limit conditions from generating an interrupt
or setting a bit in the Status Registers.
USING
THERM
AS AN INPUT
The
THERM
pin is an open-drain input/output pin. When used
as an output, it signals over-temperature conditions. When
asserted low as an output, the fan will be driven full-speed if the
THERM
-to-Fan Enable bit is set to 1 (Bit 7 of Register 0x3F).
When
THERM
is pulled low as an input, the
THERM
bit (Bit
7) of Status Register 2 is set to 1, and the fan is driven full-speed.
Note that the
THERM
-to-Fan Enable bit has no effect when-
ever
THERM
is used as an input. If
THERM
is pulled low as
an input, and the
THERM
-to-Fan Enable bit = 0, the fan will
still be driven full-speed. The
THERM
-to-Fan Enable bit only
affects the behavior of
THERM
when used as an output.
STATUS REGISTERS
All out-of-limit conditions are flagged by status bits in Status
Registers 1 and 2 (0x02, 0x03). Bits 0 and 1 (Alarm Speed, Fan
Fault) of Status Register 1, once set, may be cleared by reading
Status Register 1. Once the Alarm Speed bit is cleared, this bit
will not be reasserted on the next monitoring cycle even if the
condition still persists. This bit may be reasserted only if the
fan is no longer at Alarm Speed. Bit 1 (Fan Fault) is set when-
ever a fan tach failure is detected.
Once cleared, it will reassert on subsequent fan tach failures.
Bits 2 and 3 of Status Register 1 are the Remote Temperature
High and Low status bits. Exceeding the high or low tempera-
ture limits for the external channel sets these status bits. Reading
the status register clears these bits. However, these bits will be
reasserted if the out-of limit condition still exists on the next
monitoring cycle. Bits 6 and 7 are the Local Temperature High
and Low status bits. These behave exactly the same as the Remote
Temperature High and Low status bits. Bit 4 of Status Register
1 indicates that the Remote Temperature THERM limit has
been exceeded. This bit gets cleared on a read of Status Register
1 (see Figure 5). Bit 5 indicates a Remote Diode Error. This
bit will be a 1 if a short or open is detected on the Remote
Temperature channel on power-up. If this bit is set to 1 on
power-up, it cannot be cleared. Bit 6 of Status Register 2 (0x03)
indicates that the Local THERM limit has been exceeded. This bit
is cleared on a read of Status Register 2. Bit 7 indicates that
THERM
has been pulled low as an input. This bit can also be
cleared on a read of Status Register 2.
5
INT
REARMED
STATUS REG. READ
TEMP
THERM LIMIT
THERM
INT
Figure 5. Operation of
THERM
and
INT
Signals
Figure 5 shows the interaction between
INT
and
THERM
.
Once a critical temperature THERM limit is exceeded, both
INT
and
THERM
assert low. Reading the Status Registers
clears the interrupt and the
INT
pin goes high. However, the
THERM pin remains asserted until the measured temperature
falls 5
°
C below the exceeded
THERM
limit. This feature can be
used to CPU throttle or drive a fan full-speed for maximum
cooling. Note, that the
INT
pin for that interrupt source is not
rearmed until the temperature has fallen below the THERM
limit –5
°
C. This prevents unnecessary interrupts from tying up
valuable CPU resources.
MODES OF OPERATION
The ADM1030 has four different modes of operation. These
modes determine the behavior of the system.
1. Automatic Fan Speed Control Mode.
2. Filtered Automatic Fan Speed Control Mode.
3. PWM Duty Cycle Select Mode (directly sets fan speed under
software control).
4. RPM Feedback Mode.
相關PDF資料
PDF描述
ADM1033 Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQ Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQ-REEL Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQ-REEL7 Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQZ Thermal Monitor and Fan Speed (RPM) Controller
相關代理商/技術參數
參數描述
ADM1030ARQ 功能描述:IC SNSR TEMP/FAN PWM CTRL 16QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1030ARQ-REEL 功能描述:IC SNSR TEMP/FAN PWM CTRL 16QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1030ARQ-REEL7 功能描述:IC SNSR TEMP/FAN PWM CTRL 16QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:- 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1030ARQZ 功能描述:馬達/運動/點火控制器和驅動器 TDM & PWM FAN CNTRLRS IC RoHS:否 制造商:STMicroelectronics 產品:Stepper Motor Controllers / Drivers 類型:2 Phase Stepper Motor Driver 工作電源電壓:8 V to 45 V 電源電流:0.5 mA 工作溫度:- 25 C to + 125 C 安裝風格:SMD/SMT 封裝 / 箱體:HTSSOP-28 封裝:Tube
ADM1030ARQZ-REEL 功能描述:板上安裝溫度傳感器 TDM PWM FAN CTRLRS IC RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor