REV. 0
–2–
P
arameter
SHUTDOWN SUPPLY CURRENT
VBAT
£
2.5 V
(Deep Discharged Lockout Active)
2.5 V < VBAT
£
3.2 V (UVLO Active)
VBAT >3.2 V
OPERATING GROUND CURRENT
All LDOs On Except TCXO
All LDOs On
All LDOs On
Symbol
ICC
Conditions
Min
Typ
Max
Unit
VBAT = VBAT2 = 2.3 V
5
15
m
A
VBAT = VBAT2 = 3.15 V
VBAT = VBAT2 = 4.0 V
30
45
55
60
m
A
m
A
IGND
Minimum Loads
Minimum Loads
Maximum Loads
300
340
2.0
390
430
3.5
mA
mA
% of
Max Load
Current
V
mV
V
UVLO ON THRESHOLD
UVLO HYSTERESIS
DEEP DISCHARGED LOCKOUT
ON THRESHOLD
DEEP DISCHARGED LOCKOUT
HYSTERESIS
INPUT HIGH VOLTAGE (PWRONIN,
TCXOEN, CHGEN, GATEIN)
INPUT LOW VOLTAGE (PWRONIN,
TCXOEN, CHGEN, GATEIN)
INPUT HIGH BIAS CURRENT
(PWRONIN, TCXOEN,
CHGEN, GATEIN)
INPUT LOW BIAS CURRENT
(PWRONIN, TCXOEN,
CHGEN, GATEIN)
PWRONKEY INPUT HIGH VOLTAGE
PWRONKEY INPUT LOW VOLTAGE
PWRONKEY INPUT PULLUP
RESISTANCE TO VBAT
THERMAL SHUTDOWN THRESHOLD
2
THERMAL SHUTDOWN HYSTERESIS
ROWX CHARACTERISTICS
ROWX Output Low Voltage
VBAT
VBAT
VBAT
3.1
3.2
200
2.4
3.3
2.0
2.75
VBAT
100
mV
V
IH
2.0
V
V
IL
0.4
V
I
IH
1.0
m
A
I
IL
–1.0
m
A
V
IH
V
IL
0.7
VBAT
V
0.3
VBAT V
70
105
150
25
145
k
W
oC
oC
V
OL
PWRONKEY = Low
I
OL
= 200
m
A
PWRONKEY = High
V(ROWX) = 5 V
0.4
V
ROWX Output High Leakage Current
I
L
1
m
A
I/O LDO (VIO)
Output Voltage
Line Regulation
Load Regulation
Output Capacitor Required for Stability
Dropout Voltage
VIO
D
VIO
D
VIO
C
O
V
DO
Line, Load, Temp
Minimum Load
50
m
A
£
I
LOAD
£
25 mA
2.85
2.935
1
3
3.02
V
mV
mV
m
F
2.2
V
O
= V
INITIAL
– 100 mV
I
LOAD
= 25 mA
50
150
mV
DIGITAL CORE LDO (VCORE)
Output Voltage
Line Regulation
Load Regulation
Output Capacitor Required for Stability
VCORE
D
VCORE
D
VCORE
C
O
Line, Load, Temp
Minimum Load
50
m
A
£
I
LOAD
£
120 mA
1.78
1.85
1
8
1.92
V
mV
mV
m
F
2.2
ADP3510–SPECIFICATIONS
ELECTRICAL CHARACTERISTICS
1
(–20 C T
A
+85 C, VBAT = VBAT2 = 3.2 V–7.5 V, CVIO = CVCORE = CVAN = CVMEM = 2.2
VTCXO = 0.47
F, CVBAT = 10 F, min. loads applied on all outputs, unless otherwise noted.)
F,