參數資料
型號: ADT7463ARQ
廠商: ANALOG DEVICES INC
元件分類: 模擬信號調理
英文描述: dB COOL Remote Thermal Controller and Voltage Monitor
中文描述: SPECIALTY ANALOG CIRCUIT, PDSO24
封裝: MO-137AE, QSOP-24
文件頁數: 11/53頁
文件大小: 719K
代理商: ADT7463ARQ
REV. 0
ADT7463
–11–
4. If it is required to perform several read or write operations in
succession, the master can send a repeat start condition
instead of a stop condition to begin a new operation.
ADT7463 WRITE OPERATIONS
The SMBus specification defines several protocols for different
types of read and write operations. The ones used in the
ADT7463 are discussed below. The following abbreviations are
used in the diagrams:
S – START
P – STOP
R – READ
W – WRITE
A – ACKNOWLEDGE
A
– NO ACKNOWLEDGE
The ADT7463 uses the following SMBus write protocols:
Send Byte
In this operation, the master device sends a single command
byte to a slave device as follows:
1. The master device asserts a start condition on SDA.
2. The master sends the 7-bit slave address followed by the
write bit (low).
3. The addressed slave device asserts ACK on SDA.
4. The master sends a command code.
5. The slave asserts ACK on SDA.
6. The master asserts a STOP condition on SDA and the
transaction ends.
For the ADT7463, the send byte protocol is used to write a
register address to RAM for a subsequent single byte read from
the same address. This is illustrated in Figure 10.
S
ASLAVE
A P
1
2
3
4
5
6
REGISTER
ADDRESS
Figure 10. Setting a Register Address for Subsequent Read
If it is required to read data from the register immediately after
setting up the address, the master can assert a repeat start con-
dition immediately after the final ACK and carry out a single
byte read without asserting an intermediate stop condition.
Write Byte
In this operation, the master device sends a command byte and
one data byte to the slave device as follows:
1. The master device asserts a start condition on SDA.
2. The master sends the 7-bit slave address followed by the
write bit (low).
3. The addressed slave device asserts ACK on SDA.
4. The master sends a command code.
5. The slave asserts ACK on SDA.
6. The master sends a data byte.
7. The slave asserts ACK on SDA.
8. The master asserts a STOP condition on SDA to end the
transaction.
This is illustrated in Figure 11.
S
ASLAVE
1
2
3
4
5
6
A DATA A P
7
8
REGISTER
ADDRESS
Figure 11. Single Byte Write to a Register
ADT7463 READ OPERATIONS
The ADT7463 uses the following SMBus read protocols:
Receive Byte
This is useful when repeatedly reading a single register. The
register address needs to have been set up previously. In this
operation, the master device receives a single byte from a slave
device as follows:
1. The master device asserts a START condition on SDA.
2. The master sends the 7-bit slave address followed by the
read bit (high).
3. The addressed slave device asserts ACK on SDA.
4. The master receives a data byte.
5. The master asserts NO ACK on SDA.
6. The master asserts a STOP condition on SDA and the trans-
action ends.
In the ADT7463, the receive byte protocol is used to read a
single byte of data from a register whose address has previously
been set by a send byte or write byte operation.
S
SLAVE
ADDRESS
R
A
DATA
A
P
1
2
3
4
5
6
Figure 12. Single Byte Read from a Register
ALERT RESPONSE ADDRESS
Alert Response Address (ARA) is a feature of SMBus devices
that allows an interrupting device to identify itself to the host
when multiple devices exist on the same bus.
The
SMBALERT
output can be used as an interrupt output or
can be used as an
SMBALERT
. One or more outputs can be
connected to a common
SMBALERT
line connected to the
master. If a device’s
SMBALERT
line goes low, the following
procedure occurs:
1.
SMBALERT
is pulled low.
2. Master initiates a read operation and sends the Alert
Response Address (ARA = 0001 100). This is a general
call address that must not be used as a specific device
address.
3. The device whose
SMBALERT
output is low responds to
the Alert Response Address, and the master reads its device
address. The address of the device is now known and it can
be interrogated in the usual way.
4. If more than one device’s
SMBALERT
output is low, the
one with the lowest device address will have priority in accor-
dance with normal SMBus arbitration.
5. Once the ADT7463 has responded to the Alert Response
Address, the master must read the Status Registers and the
SMBALERT
will only be cleared if the error condition has
gone away.
SMBUS TIMEOUT
The ADT7463 includes an SMBus Timeout feature. If there is
no SMBus activity for 35 ms, the ADT7463 assumes that the bus
is locked and releases the bus. This prevents the device from
locking or holding the SMBus expecting data. Some SMBus
controllers cannot handle the SMBus Timeout feature, so it
can be disabled.
CONFIGURATION REGISTER 1 – Register 0x40
<6>
TODIS = 0;
SMBus Timeout ENABLED (default)
<6>
TODIS = 1;
SMBus Timeout DISABLED
相關PDF資料
PDF描述
ADT7466 dBCool Remote Thermal Controller and Voltage Monitor
ADT7466ARQZ dBCool Remote Thermal Controller and Voltage Monitor
ADT7466ARQZ-REEL dBCool Remote Thermal Controller and Voltage Monitor
ADT7466ARQZ-REEL7 dBCool Remote Thermal Controller and Voltage Monitor
ADT7516 SPI/I2C Compatible, Temperature Sensor, Four Channel ADC and Quad Voltage Output DAC
相關代理商/技術參數
參數描述
ADT7463ARQ-REEL 功能描述:IC SENSOR TEMP FAN-CTRL 24QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:dBCool® 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADT7463ARQ-REEL7 功能描述:IC SENSOR TEMP FAN-CTRL 24QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:dBCool® 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADT7463ARQZ 功能描述:馬達/運動/點火控制器和驅動器 SYS MGMT CNTRLR IC RoHS:否 制造商:STMicroelectronics 產品:Stepper Motor Controllers / Drivers 類型:2 Phase Stepper Motor Driver 工作電源電壓:8 V to 45 V 電源電流:0.5 mA 工作溫度:- 25 C to + 125 C 安裝風格:SMD/SMT 封裝 / 箱體:HTSSOP-28 封裝:Tube
ADT7463ARQZ-R7 功能描述:板上安裝溫度傳感器 SYS MGMT CNTRLR IC RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
ADT7463ARQZ-REEL 功能描述:板上安裝溫度傳感器 SYS MGMT CNTRLR IC RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
主站蜘蛛池模板: 彭水| 蕲春县| 崇阳县| 荃湾区| 乌兰浩特市| 泗洪县| 安康市| 滨海县| 阳高县| 贡山| 台中县| 奈曼旗| 柏乡县| 阿尔山市| 韶山市| 高要市| 朔州市| 繁昌县| 福海县| 绍兴县| 邢台县| 滨州市| 内黄县| 微山县| 梅河口市| 新丰县| 黔江区| 出国| 蒙自县| 澄迈县| 文山县| 鹤山市| 华容县| 华亭县| 永州市| 藁城市| 毕节市| 尖扎县| 惠安县| 乌审旗| 城固县|