欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: IS42S16800A-6TL
廠商: INTEGRATED SILICON SOLUTION INC
元件分類: DRAM
英文描述: 16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
中文描述: 8M X 16 SYNCHRONOUS DRAM, 5.4 ns, PDSO54
封裝: LEAD FREE, PLASTIC, TSOP2-54
文件頁數: 53/66頁
文件大小: 556K
代理商: IS42S16800A-6TL
Integrated Silicon Solution, Inc. — www.issi.com —
1-800-379-4774
ADVANCED INFORMATION
Rev. 00A
06/01/02
53
ISSI
IS42S81600A, IS42S16800A, IS42S32400A
IS42LS81600A, IS42LS16800A, IS42LS32400A
CLK
CKE
HIGH
ALL BANKS
BANK SELECT
BANK ADDRESS
CS
RAS
CAS
WE
A0-A9, A11
A10
BA0, BA1
DON'T CARE
CLK
CKE
COMMAND
NOP
NOP
ACTIVE
t
CKS
t
CKS
All banks idle
Enter
power-down mode
Exit power-down mode
t
RCD
t
RAS
t
RC
Input buffers gated
off
less than 64ms
PRECHARGE Command
POWER-DOWN
POWER-DOWN
Power-down occurs if CKE is registered LOW coincident
with a NOP or COMMAND INHIBIT when no accesses are
in progress. If power-down occurs when all banks are idle,
this mode is referred to as precharge power-down; if power-
down occurs when there is a row active in either bank, this
mode is referred to as active power-down. Entering power-
down deactivates the input and output buffers, excluding
CKE, for maximum power savings while in standby. The
device may not remain in the power-down state longer than
the refresh period (64ms) since no refresh operations are
performed in this mode.
The power-down state is exited by registering a NOP or
COMMAND INHIBIT and CKE HIGH at the desired clock
edge (meeting t
CKS
). See figure below.
PRECHARGE
The PRECHARGE command (see figure) is used to deac-
tivate the open row in a particular bank or the open row in all
banks. The bank(s) will be available for a subsequent row
access some specified time (t
RP
) after the PRECHARGE
command is issued. Input A10 determines whether one or
all banks are to be precharged, and in the case where only
one bank is to be precharged, inputs BA0, BA1 select the
bank. When all banks are to be precharged, inputs BA0,
BA1 are treated as “Don’t Care.” Once a bank has been
precharged, it is in the idle state and must be activated prior
to any READ or WRITE commands being issued to that
bank.
相關PDF資料
PDF描述
IS42S16800A-7T 16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
IS42S16800A-7TI 16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
IS42S16800A-10TI 16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
IS42S16800A-10TL 16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
IS42S16800A-10TLI 16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
相關代理商/技術參數
參數描述
IS42S16800A-7B 制造商:ICSI 制造商全稱:Integrated Circuit Solution Inc 功能描述:16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
IS42S16800A-7BI 制造商:ICSI 制造商全稱:Integrated Circuit Solution Inc 功能描述:16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
IS42S16800A-7BL 制造商:Integrated Silicon Solution Inc 功能描述:
IS42S16800A-7T 制造商:ISSI 制造商全稱:Integrated Silicon Solution, Inc 功能描述:16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
IS42S16800A-7TI 制造商:ICSI 制造商全稱:Integrated Circuit Solution Inc 功能描述:16Meg x 8, 8Meg x16 & 4Meg x 32 128-MBIT SYNCHRONOUS DRAM
主站蜘蛛池模板: 东光县| 怀仁县| 凤庆县| 兴山县| 航空| 晋城| 洛隆县| 牟定县| 平度市| 无锡市| 仁布县| 郓城县| 怀来县| 保山市| 连云港市| 五家渠市| 元氏县| 蓬莱市| 龙川县| 靖边县| 临江市| 玉山县| 商丘市| 错那县| 凭祥市| 册亨县| 通海县| 喜德县| 大新县| 高邮市| 海城市| 卓尼县| 盐津县| 江阴市| 油尖旺区| 富顺县| 巫溪县| 淮南市| 托克逊县| 金寨县| 尼木县|