tfs110c.doc
VI TELEFILTER
version1.3
07.06.2000.
Filter specification
TFS 110 C - 1/5
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No
liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such
product(s) or information.
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
Measurement condition
Ambient temperature :
Input power level :
Terminating impedances :
Characteristics
Remark: Reference level for the relative attenuation
arel
of the
TFS 110 C
is the minimum of the pass band attenuation
amin
. The minimum of the
pass band attenuation
amin
is defined as the insertion loss
ae.
The centre (reference) frequency
fc
is the arithmetic mean value of the upper and
lower frequencies at the
3 dB
filter attenuation level relative to the insertion loss
ae
.
Data
23° C
0 dBm
for input:
for output:
890
||
- 5,6 pF
680
||
- 5,9 pF
typ. value
tolerance / limit
Insertion loss
(Reference level)
ae
11,9 dB
max. 13 dB
Centre frequency
fc
at ambient temperature T
A
(
f
CAT
)
(3 dB-BW)
110,592 ± 0,035 MHz
Pass band shape
Gaussian
Bandwidth
at ambient temperature
:
3 dB bandwidth
10 dB bandwidth
20 dB bandwidth
30 dB bandwidth
40 dB bandwidth
965 kHz
1695 kHz
2255 kHz
2600 kHz
2840 kHz
min. 900 kHz
min. 1600 kHz
max. 2420 kHz
max. 2700 kHz
max. 3070 kHz
Relative attenuation
arel
fc ± 450 kHz
fc ± 450 kHz … fc ± 800 kHz
fc ± 1210 kHz … fc ± 1395 kHz
fc ± 1395 kHz … fc ± 1535 kHz
fc ± 1535 kHz … fc ± 10 MHz
-
max.
max. 10 dB
min.
20 dB
min.
30 dB
min.
40 dB
3 dB
45...55 dB
<
Group delay ( mean value ) :
Group delay ripple (p-p) :
Deviation from linear phase (p-p):
fc … fc ± 800 kHz
fc … fc ± 800 kHz
1,2 μs
160 ns
3 °
max. 300 ns
Frequency inversion temperature ( T
o
)
10° C
Temperature coefficient:
Frequency deviation of fc over temperature: * )
1-st order [ Tc
f
(1) ]
2-st order [ Tc
f
(2) ]
+ 1,7 ppm/K
- 0,06 ppm/K2
fc(Hz) = [ Tc
f
(1) x (T - T
o
) + Tc
f
(2) x (T - T
o
)2 ] x
f
To
(MHz)
Operating temperature range
Storage temperature range
- 10 °C ... + 60 °C
- 40 °C ... + 85 °C
Input power level
max. 10 dBm.
Permissible DC voltage
Permissible AC voltage
VDC
Vpp
-
-
12 V
10 V
* ) f
To
is reference frequency
fc
at frequency inversion temperature (
T
o
)
Generated:
Checked/Approved:
Dunzow W.P.
Dr. Bert Wall