tfs 80D1doc
VI TELEFILTER
Version 1.0
06.01.02
Filter Specification
TFS 80 D1 - 1/3
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
1. Measurement condition :
Ambient temperature T
A
:
Input power level:
Terminating impedances in fc:
23 °C
0
for input:
for output:
dBm.
50
0 pF
50
0 pF,
2. Characteristics
Remark:
Reference level for the relative attenuation
arel
of the
TFS 80 D
is the minimum of the pass band attenuation
amin
. The minimum of the pass band
attenuation amin is defined as the insertion loss
ae
. The reference frequency
fc
is the arithmetic mean value of the upper and lower frequencies at
the
3 dB
filter attenuation level relative to the insertion loss
ae
.
Data
typ. value
tolerance / limit
Insertion loss
(Reference level)
ae
15
dB
max. 16
dB
Centre frequency
fc
at ambient temperature
( f
CAT
)
80,07
MHz
80,07 ± 0,02
MHz
Pass band (-3 dB)
f
C
- 90 kHz ... f
C
+ 90 kHz
Bandwidth
at ambient temperature
:
3 dB - band width
184
kHz
min. 180
kHz
Relative attenuation
arel
fc ± 90
fc + 400
fc - 200
fc ± 500
fc ± 1,0
fc - 35
fc + 35
fc
kHz
-
-
max. 3
dB
fc + 200
fc - 400
fc ± 400
fc ± 0,5
fc - 1,0
fc + 1,0
kHz
kHz
-
-
min. 19
dB
kHz
kHz
-
-
min. 14
dB
kHz
kHz
40
dB
min. 35
dB
MHz
MHz
52...65
dB
min. 50
dB
MHz
MHz
64...70
dB
min. 60
dB
MHz
MHz
62...70
dB
min. 58
dB
Average group delay in pass band:
4,12
μs
-
Group delay ripple:
fc – 100 kHz .....fc
fc ... fc + 100 kHz
Deviation from linear phase (p-p)
300
ns
max. 600
ns
600
ns
max. 700
ns
fc ... fc ± 100 kHz
5,2 °
Crosstalk attenuation compared to main signal
55...60
dB
Triple transit attenuation compared to main signal
33...34
dB
Frequency inversion temperature ( T
o
)
20
°C
Temperature coefficient of frequency ( Tc
f
)
-0,075
ppm/K2
-
Frequency deviation of fc over temperature T : *)
fc(Hz) = Tc
f
(ppm/K) x (T - T
o
)2 x f
To
(MHz)
Operating temperature range
- 25 °C ... + 75 °C
Storage temperature range
- 30 °C ... + 85 °C
Input power level
-
max. + 10
dBm
* ) f
To
is reference frequence
fc
at frequency inversion temperature (
T
o
)
Generated: Wadim P. Dunzow
Checked/Approved: Dr. Bert Wall