09-2011, Rev. 0911
www.te.com
2011 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Datasheets and product specification ac-
cording to IEC 61810-1 and to be used only
together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
n
Small power relay
n
Limiting continuous current 30A
n
Minimal weight
n
Low noise operation
n
Wave (THT) and reflow (THR/pin-in-paste) solderable versions
n
For single version refer to Single Micro Relay K
Typical applications
Car alarm, door control, door lock, hazard warning signal, heated front/rear
screen, immobilizer, lamps front/rear/fog light, interior lights, seat control,
sun roof, turn signal, window lifter, wiper control.
Contact Data
Contact arrangement
Rated voltage
Rated current, form A/form B
Limiting continuous current, form A/form B
23°C
85°C
Limiting making current
Limiting breaking current
Contact material
Min. recommended contact load
Initial voltage drop at 10A, typ./max.
Operate/release time
Electrical endurance
-40°C, +25°C, +85°C and 14 VDC,
form C (CO), cyclic temperature
motor reverse blocked, 25A, 0.77mH
wiper
25A make/5A break,
generator peak -20A on NC, L=1.0mH
form A contact (NO), cyclic temperature
resistive 20A
2 form C, 2 CO
10/12VDC
NO/NC
30A/25A
30/25A
20/15A
40A
1)
30A
AgSnO
1A at 5VDC
2)
30/300 mV
typ. 3/1.5ms
3)
>1x10
5
ops.
>1x10
6
ops.
>3x10
5
ops.
Contact Data
(continued)
Mechanical endurance
1) The values apply to a resistive or inductive load with suitable spark suppression and at
maximum 13.5VDC for 12VDC load voltages.For a load current duration of maximum 3s
for a make/break ratio of 1:10.
2) See chapter Diagnostics of Relays in our Application Notes or consult the internet at
http://relays.te.com/appnotes/
3) Measured at nominal voltage without coil suppression unit. A low resistive suppression
device in parallel to the relay coil increases the release time and reduces the lifetime
caused by increased erosion and/or higher risk of contact tack welding
> 5x10
6
ops.
Coil Data
Rated coil voltage
12VDC
Coil versions, DC coil
Coil
code
001
002
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Rated
voltage
VDC
12
10
Operate
voltage
VDC
6.9
5.7
Release
voltage
VDC
1.5
1.25
Coil
Rated coil
power
mW
567
552
resistance
±10%
254
181
Coil operating range
Insulation Data
Initial dielectric strength
between open contacts
between contact and coil
500VAC
rms
500VAC
rms
Double Micro Relay K (THT – THR)
Automotive Relays
PCB Double Relays
Max. DC load breaking capacity
Load limit curve I: safe shutdown, arc extinguishes during transit time.
Load limit curve II: safe shutdown, no stationary arc.
Load limit curves measured with low inductive resistors verified for 1000 switching events.
0
50
100
150
200
250
300
-40
-20
0
20
Ambient temperature in °C
40
60
80
100
120
Umax
Uop (E=0V)
Does not take into account the temperature rise due to the contact current
E = pre-energization
086C/R2_fcw1b