H04-004-03
13
MS5F5326
11. Reliability test results
Reliability Test Items
Test
cate-
gories
Test items
Test methods and conditions
Reference
norms
EIAJ
ED-4701
A - 111
Method 1
A - 112
Method 2
A - 121
Number
of sample
Accept-
ance
number
1 Terminal Strength
(Pull test)
2 Mounting Strength
Pull force
Test time
Screw torque
Test time
Range of frequency : 10 ~ 500Hz
Sweeping time
Acceleration
Sweeping direction : Each X,Y,Z axis
Test time
Maximum acceleration : 1000G
Pulse width
Direction
Test time
Solder temp.
Immersion time
Test time
Each terminal should be Immersed in solder
within 1~1.5mm from the body.
Solder temp.
Immersion time
Test time
Each terminal should be Immersed in solder
within 1~1.5mm from the body.
Storage temp.
Test duration
Storage temp.
Test duration
Storage temp.
Relative humidity
Test duration
Test temp.
Atmospheric pressure : 2.03×10
5
Pa
: 20N
: 10±1 sec.
: 2.5 ~ 3.5 N
m (M5)
: 10±1 sec.
5
( 1 : 0 )
5
( 1 : 0 )
3 Vibration
5
( 1 : 0 )
: 15 min.
: 10G
: 6 hr. (2hr./direction)
4 Shock
A - 122
5
( 1 : 0 )
: 0.5msec.
: Each X,Y,Z axis
: 3 times/direction
: 235±5
℃
: 5±1sec.
: 1 time
5 Solderabitlity
A - 131
5
( 1 : 0 )
6 Resistance to
Soldering Heat
: 260±5
℃
: 10±1sec.
: 1 time
A - 132
5
( 1 : 0 )
1 High Temperature
Storage
2 Low Temperature
Storage
3 Temperature
Humidity
Storage
4 Unsaturated
Pressure Cooker
: 125±5
℃
: 1000hr.
: -40±5
℃
: 1000hr.
: 85±3
℃
: 85±5%
: 1000hr.
: 121
℃
B - 111
5
( 1 : 0 )
B - 112
5
( 1 : 0 )
B - 121
5
( 1 : 0 )
B - 123
5
( 1 : 0 )
(Reference value)
: 20hr.
+3
: Low temp. -40
-5
℃
+5
High temp. 125
-5
℃
Test duration
5 Temperature
Cycle
B - 131
5
( 1 : 0 )
Test temp.
RT 5 ~ 35
℃
: High ~ RT ~ Low ~ RT
1hr. 0.5hr. 1hr. 0.5hr.
: 100 cycles
+0
: High temp. 100
-5
℃
+5
Low temp. 0
-0
℃
Dwell time
Number of cycles
6 Thermal Shock
B - 141
5
( 1 : 0 )
Test temp.
Used liquid : Water with ice and boiling water
Dipping time
Transfer time
Number of cycles
: 5 min. par each temp.
: 10 sec.
: 10 cycles
M
E
6