AD7940
POWER-DOWN MODE
This mode is intended for use in applications where slower
throughput rates are required. Either the ADC is powered down
between each conversion, or a series of conversions may be
performed at a high throughput rate, and then the ADC is pow-
ered down for a relatively long duration between these bursts of
several conversions. When the AD7940 is in power-down, all
analog circuitry is powered down.
Rev. 0 | Page 14 of 20
To enter power-down, the conversion process must be inter-
rupted by bringing CS high anywhere after the second falling
edge of SCLK and before the 10th falling edge of SCLK as
shown in Figure 17. Once CS has been brought high in this
window of SCLKs, the part will enter power-down, the
conversion that was initiated by the falling edge of CS will be
terminated, and SDATA will go back into three-state. If CS is
brought high before the second SCLK falling edge, the part will
remain in normal mode and will not power down. This will
avoid accidental power-down due to glitches on the CS line.
In order to exit this mode of operation and power up the
AD7940 again, a dummy conversion is performed. On the fal-
ling edge of CS, the device will begin to power up and will
continue to power up as long as CS is held low until after the
falling edge of the 10th SCLK. The device will be fully powered
up once at least 16 SCLKs (or approximately 6 μs) have elapsed
and valid data will result from the next conversion as shown in
Figure 18. If CS is brought high before the 10th falling edge of
SCLK, regardless of the SCLK frequency, the AD7940 will go
back into power-down again. This avoids accidental power-up
due to glitches on the CS line or an inadvertent burst of 8 SCLK
cycles while CS is low. So although the device may begin to
power-up on the falling edge of CS, it will power down again on
the rising edge of CS as long as it occurs before the 10th SCLK
falling edge.
0
SCLK
SDATA
1
2
10
16
THREE-STATE
CS
Figure 17. Entering Power-Down Mode
0
1
10
16
1
16
SDATA
SCLK
CS
INVALID DATA
VALID DATA
THE PART IS FULLY POWERED
UP WITH V
IN
FULLY ACQUIRED
THE PART BEGINS
TO POWER UP
t
POWER UP
Figure 18. Exiting Power-Down Mode
相關PDF資料
PDF描述
AD7940BRJ-REEL7 3mW, 100kSPS, 14-Bit ADC in 6-Lead SOT-23
AD7680 3mW, 100kSPS, 14-Bit ADC in 6-Lead SOT-23
AD7683 3mW, 100kSPS, 14-Bit ADC in 6-Lead SOT-23
AD7685 3mW, 100kSPS, 14-Bit ADC in 6-Lead SOT-23
AD7687 +3.3V, 2.7Gbps Dual 2 x 2 Crosspoint Switch
相關代理商/技術參數
參數描述
AD7947BCP 制造商:Analog Devices 功能描述:ADC SGL SAR 500KSPS 14BIT SERL 10LFCSP - Bulk
AD7948 制造商:AD 制造商全稱:Analog Devices 功能描述:+3.3 V/+5 V Multiplying 12-Bit DACs
AD7948AN-B 制造商:Rochester Electronics LLC 功能描述:BYTE 12-B IOUT DAC IC - Bulk 制造商:Analog Devices 功能描述:
AD7948ANZ-B 功能描述:IC DAC 12BIT MULT PARALL 20DIP RoHS:是 類別:集成電路 (IC) >> 數據采集 - 數模轉換器 系列:- 標準包裝:2,400 系列:- 設置時間:- 位數:18 數據接口:串行 轉換器數目:3 電壓電源:模擬和數字 功率耗散(最大):- 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:36-TFBGA 供應商設備封裝:36-TFBGA 包裝:帶卷 (TR) 輸出數目和類型:* 采樣率(每秒):*
AD7948ARS-B 功能描述:IC DAC 12BIT MULT PARALL 20-SSOP RoHS:否 類別:集成電路 (IC) >> 數據采集 - 數模轉換器 系列:- 標準包裝:2,400 系列:- 設置時間:- 位數:18 數據接口:串行 轉換器數目:3 電壓電源:模擬和數字 功率耗散(最大):- 工作溫度:-40°C ~ 85°C 安裝類型:表面貼裝 封裝/外殼:36-TFBGA 供應商設備封裝:36-TFBGA 包裝:帶卷 (TR) 輸出數目和類型:* 采樣率(每秒):*
主站蜘蛛池模板: 河池市| 宁武县| 龙泉市| 化德县| 娱乐| 松江区| 琼结县| 万全县| 融水| 江源县| 阿拉善盟| 绥化市| 阳春市| 卢氏县| 桓台县| 涿州市| 西宁市| 宁陵县| 峡江县| 澜沧| 贺兰县| 衡山县| 湖口县| 辽中县| 临桂县| 南京市| 湖南省| 兴城市| 清远市| 思茅市| 扶余县| 石台县| 东安县| 咸阳市| 北京市| 宁阳县| 郸城县| 伊川县| 汶上县| 健康| 区。|