ADM1026
Status Register 4 also stores inputs from two other interrupt
sources that operate in a different way from the other status bits.
If automatic fan speed control (AFC) is enabled, Bit 4 of Status
Register 4 is set whenever a fan starts or stops. This bit causes a
one-off INT output as shown in Figure 52. It is cleared during
the next monitoring cycle and if INT has been cleared, it does
not cause INT to be reasserted.
Rev. A | Page 29 of 56
INT
INT CLEARED BY STATUS REGULAR 1 READ, BIT 2
OF CONFIGURATION REGULAR 1 SET, OR ARA
FAN ON
FAN OFF
0
Figure 52. Assertion of INT Due to AFC Event
In a similar way, a change of state at the THERM output
(described in more detail later), sets Bit 3 of Status
Register 4 and causes a one-off INT output. A change of state at
the THERM output also causes Bit 0 of Status Register 1, Bit 1
of Status Register 1, or Bit 0 of Status Register 4 to be set,
depending on which temperature channel caused the THERM
event. This bit is reset during the next monitoring cycle,
provided the temperature channel is within the normal high
and low limits.
Fan Inputs
Fan inputs generate interrupts in a similar way to analog/
temperature inputs, but as the analog/ temperature inputs and
fan inputs have different monitoring cycles, they have separate
interrupt circuits. As the speed of each fan is measured, the
output of the fan speed counter is stored in a value register. The
result is compared to the fan speed limit and is used to set or
clear a bit in Status Register 3. In this case, the fan is monitored
only for under-speed (fan counter > fan speed limit). Mask
Register 3 is used to mask fan interrupts. After mask gating, the
fan status bits are OR’ed together and used to set a latch, whose
output is OR’ed with other interrupt sources to produce the INT
output.
Like the analog/temp interrupt, an INT output caused by an
out-of-limit fan speed measurement, once cleared, is not
reasserted until the end of the next monitoring cycle, although
other interrupt sources may cause INT to be asserted.
GPIO and CI Pins. When GPIO pins are configured as inputs,
asserting a GPIO input (high or low, depending on polarity) sets
the corresponding GPIO status bit in Status Registers 5 and 6, or
Bit 7 of Status Register 4 (GPIO16). A chassis intrusion event
sets Bit 6 of Status Register 4.
The GPIO and CI status bits, after mask gating, are OR’ed
together and OR’ed with other interrupt sources to produce the
INT output. GPIO and CI interrupts are not latched and cannot
be cleared by normal interrupt clearing. They can only be
cleared by masking the status bits or by removing the source of
the interrupt.
ENABLING AND CLEARING INTERRUPTS
The INT output is enabled when Bit 1 of Configuration
Register 1 (INT_Enable) is high, and Bit 2 (INT_Clear) is low.
INT may be cleared if
Status Register 1 is read. Ideally, if polling the status
registers trying to identify interrupt sources, Status
Register 1 should be polled last, because a read of Status
Register 1 clears all the other interrupt status registers.
The ADM1026 receives the alert response address (ARA)
(0001 100) over the SMBus.
Bit 2 of Configuration Register 1 is set.
Bidirectional THERM Pin
The ADM1026 has a second interrupt pin (GPIO16/THERM
Pin 42) that responds only to critical thermal events. The
THERM pin goes low whenever a THERM limit is exceeded.
This function is useful for CPU throttling or system shutdown.
In addition, whenever THERM is activated, the PWM and DAC
outputs go full scale to provide fail-safe system cooling. This
output is enabled by setting Bit 4 of Configuration Register 1
(Register 00h). Whenever a THERM limit is exceeded, Bit 3 of
Status Register 4 (Reg 23h) is set, even if the THERM function
is disabled (Bit 4 of Configuration Register 1 = 0). In this case,
the THERM status bit is set, but the PWM and DAC outputs are
not forced to full scale.
Three thermal limit registers are provided for the three
temperature sensors at Addresses 0Dh to 0Fh. These registers
are dedicated to the THERM function and none of the other
limit registers have any effect on the THERM output.
If any of the temperature measurements exceed the correspond-
ing limit, THERM is asserted (low) and the DAC and PWM
outputs go to maximum to drive any cooling fans to full speed.
To avoid cooling fans cycling on and off continually when the
temperature is close to the limit, a fixed hysteresis of 5°C is
provided. THERM is only deasserted when the measured
temperature of all three sensors is 5°C below the limit.
Whenever the THERM output changes, INT is asserted, as
shown in Figure 54. However, this is edge-triggered, so if INT
is subsequently cleared by one of the methods previously
described, it is not reasserted, even if THERM remains asserted.
THERM causes INT to be reasserted only when it changes state.
相關PDF資料
PDF描述
ADM1026JST Circular Connector; No. of Contacts:28; Series:LJT06R; Body Material:Aluminum; Connecting Termination:Crimp; Connector Shell Size:19; Circular Contact Gender:Pin; Circular Shell Style:Straight Plug; Insert Arrangement:19-28
ADM1030ARQ Intelligent Temperature Monitor and PWM Fan Controller
ADM1030 Circular Connector; No. of Contacts:66; Series:LJT06R; Body Material:Aluminum; Connecting Termination:Crimp; Connector Shell Size:19; Circular Contact Gender:Socket; Circular Shell Style:Straight Plug; Insert Arrangement:19-35
ADM1033 Thermal Monitor and Fan Speed (RPM) Controller
ADM1033ARQ Thermal Monitor and Fan Speed (RPM) Controller
相關代理商/技術參數
參數描述
ADM1026JSTZ-REEL7 制造商:Analog Devices 功能描述:IC SYSTEM MONITOR 制造商:ON Semiconductor 功能描述:IC SYSTEM MONITOR
ADM1027 制造商:AD 制造商全稱:Analog Devices 功能描述:dBCOOL-TM Remote Thermal Controller and Voltage Monitor
ADM1027ARQ 功能描述:IC THER CTRL VOLT/MONITOR 24QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:dBCool® 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1027ARQ-REEL 功能描述:IC REMOTE THERMAL CTRLR 24-QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:dBCool® 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
ADM1027ARQ-REEL7 功能描述:IC REMOTE THERMAL CTRLR 24-QSOP RoHS:否 類別:集成電路 (IC) >> PMIC - 熱管理 系列:dBCool® 標準包裝:1 系列:- 功能:溫度監控系統(傳感器) 傳感器類型:內部和外部 感應溫度:-40°C ~ 125°C,外部傳感器 精確度:±2.5°C 本地(最大值),±5°C 遠程(最大值) 拓撲:ADC,比較器,寄存器庫 輸出類型:2 線 SMBus? 輸出警報:無 輸出風扇:無 電源電壓:2.7 V ~ 5.5 V 工作溫度:-40°C ~ 125°C 安裝類型:表面貼裝 封裝/外殼:SOT-23-8 供應商設備封裝:SOT-23-8 包裝:Digi-Reel® 其它名稱:296-22675-6
主站蜘蛛池模板: 上蔡县| 余江县| 米脂县| 玛纳斯县| 肇州县| 滨州市| 苗栗县| 牟定县| 台山市| 石棉县| 贵港市| 阿瓦提县| 保德县| 阳原县| 平顶山市| 海林市| 桃园市| 丰城市| 诸城市| 新蔡县| 双江| 九江县| 中宁县| 安徽省| 加查县| 文安县| 峨眉山市| 互助| 崇文区| 青浦区| 富锦市| 嵊泗县| 石屏县| 于田县| 凤冈县| 德阳市| 沾化县| 木兰县| 定结县| 乐清市| 昌宁县|