3
PSRR (
V
OUT
/
V
BUS
)
PSRRac
120Hz
-65
dB
Amplifier Output Offset Voltage
|V
OS
|
DC voltage across the speaker, load = 8
2
mV
Amplifier Output Impedance
Z
OUT
Measured at 1kHz and 10W Output
16
m
Damping Factor
DF
Measured at 1kHz and 10W Output
500
ADDITIONAL CHARACTERISTICS
Cutoff Frequency, Referenced to 1kHz
F
UPPER8
-3dB, R
LOAD
= 8
at 10W Output
80
kHz
Cutoff Frequency, Referenced to 1kHz
F
UPPER4
-3dB, R
LOAD
= 4
at 10W Output
70
kHz
20kHz Response, Referenced to 1kHz
F
R
at 20kHz
Output at 20kHz and 10W, R
LOAD
= 8
-0.5
dB
Power Bandwidth
P
BW
Maximum Frequency for Full Power R
LOAD
= 8
28
kHz
Slew Rate
SR
Maximum rate of change of the output voltage
18
V/
μ
s
Maximum Switching Ripple on Output
F
PWM
Full Output Power, R
LOAD
= 8
12.0
V
Input Gain
A
V
Either Inverting or non inverting input. Unused
input returned to analog ground
26
dB
Input Impedance, Inverting Input
R
-INPUT
Differential amplifier input, other input grounded
10
k
Input Impedance, Non Inverting Input
R
+INPUT
Differential amplifier input, other input grounded
5
k
Output Signal Phasing
Phasing
Positive going signal on non Inverting input
results in negative going amplifier output
180
Degrees
Over Temperature Shut Down
OT
SD
Rising temperature to shutdown amplifier.
Set by an external thermistor
110
o
C
Over Temperature Hysteresis
OT
H
Difference between rising and falling temperature
shut down and start up points
10
o
C
Amplifier Output Current Limit
I
L
Absolute Value
25
A
Amplifier Output Current Limit Time
(Note 3)
T
IL
Time the amplifier must be in current limiting before
shutdown
50
ms
NOTES:
2. At this power level, the soft clipping circuitry is beginning to activate. It functions to “round off” peaks rather than hard limit as in most linear
amplifiers. This helps to give this amplifier a pleasing sound during limiting. Moreover, this feature also makes the amplifier “sound louder”.
3. This time allows the amplifier to reproduce large, sustained peaks without shutting down, yet is adequate to protect the amplifier output from
shorted speaker lines.
Electrical Specifications
R
LOAD
= 8
, V
BUS
=
±
110V, Supply Source Resistance < 2.5
, Storage Capacitor > 12,000
μ
F, 12VFLT = 12V,
+/-12V = +/-12V
(Continued)
PARAMETER
SYMBOL
TEST CONDITIONS
T
A
= 25
o
C
UNITS
TYP
HCA600ACREF