14
Configuration Dialog Box
The configuration dialog box is called up by choosing the
“Board Settings” menu item under the “Configure” main
menu choice. This form contains options pertaining to the
evaluation board. Changes made on this form take place
immediately (unlike changes to the “tabbed-notebook” which
must be downloaded to take effect.
The common configuration options are:
Communication Port
This configuration option allows the user to specify which
communication (printer) port to use when
downloading/uploading the evaluation board.
Reset
This radio button directly controls the reset pin on the
HSP3824 chip.
RX_PE
This radio button directly controls the RX_PE pin on the
HSP3824 chip.
TX_PE
This radio button directly controls the TX_PE pin on the
HSP3824 chip.
Part Number
This configuration option will allow the user to specify the
part number of the chip. Currently, there is only one part
number, so the user shouldn’t need to modify this field.
The following options apply to the Rev. C Evaluation Board
only:
Board Selection
This configuration option allows the user to specify which
board identifier to use when downloading/uploading the
evaluation board.
Data Mode
The Rev. C evaluation board is capable of generating a data
stream that can be packetized or continuous. This option
allows the user to select the type of data stream to use.
Packet Length
This configuration option along with the “Data Mode” option
allows the user to specify the length of the packets
generated by the evaluation board.
COMM PORT
LPT1:
LPT2:
LPT3:
BOARD SELECT
BOARD 0
BOARD 1
DATA MODE
CONTINUOUS
PACKETIZED
RESET
ACTIVE
INACTIVE
RX_PE
INACTIVE
ACTIVE
TX_PE
INACTIVE
ACTIVE
TOGGLE
RESET
RX_PE
TX_PE
PACKET LENGTH (BITS)
PART NUMBER
EXIT
PRINT