tfs 80D2doc
VI TELEFILTER
Version 1.1
16.05.2000.
Filter Specification
TFS 80 D2 - 1/4
VI TELEFILTER
Potsdamer Strae 18
D 14 513 TELTOW / Germany
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
E-Mail: tft@telefilter.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Vectron International, Inc.
267 Lowell Road
Hudson, NH 03051 / USA
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: vti@vtinh.com
1. Measurement condition :
Ambient temperature T
A
:
Input power level:
Terminating impedances in fc:
23 °C
0
for input:
for output:
dBm.
50
- 56 pF
50
0 pF,
2. Characteristics
Remark:
Reference level for the relative attenuation
arel
of the
TFS 80 D2
is the minimum of the pass band attenuation
amin
. The minimum of the pass
band attenuation amin is defined as the insertion loss
ae
. The reference frequency
fc
is the arithmetic mean value of the upper and lower
frequencies at the
3 dB
filter attenuation level relative to the insertion loss
ae
.
Data
typ. value
tolerance / limit
Insertion loss
(Reference level)
ae
14,0 dB
max. 14,5 dB
Centre frequency
fc
at ambient temperature
( f
CAT
)
80,07 MHz
80,07 ± 0,01 MHz
Pass band (-3 dB)
f
C
- 100 kHz ... f
C
+ 100 kHz
Bandwidth
at ambient temperature
:
3 dB - band width
10 dB - band width
20 dB - band width
36 dB - band width
45 dB - band width
212 kHz
350 kHz
450 kHz
770 kHz
990 kHz
min. 200 kHz
max. 800 kHz
max.1000 kHz
Relative attenuation
arel
fc
kHz
...
.... fc - 200 kHz
...
fc + 400 kHz
...
fc ± 500 kHz
...
fc ± 1,0 MHz
...
fc ± 35 MHz
fc ± 100 kHz
- -
- -
- -
max.
min.
min.
min.
min.
min.
3 dB
11 dB
19 dB
36 dB
45 dB
50 dB
fc - 400
fc + 200 kHz
fc ± 400 kHz
fc ± 500 kHz
fc ± 1,0
40 dB
50...60 dB
60...70 dB
kHz
Group delay ( mean value in PB ):
Group delay ripple :
4,12 μs
500 ns
700 ns
5,2°
fc – 100 kHz .....fc
fc ... fc + 100 kHz
max. 600 ns
max. 750 ns
Deviation from linear phase in PB (p-p):
Triple transit attenuation compared to main signal
Crosstalk
33...34 dB
55...60 dB
Frequency inversion temperature ( T
o
)
Temperature coefficient of frequency ( Tc
f
)
Frequency deviation of fc over temperature: * )
10°
-0,045 ppm/K2
fc(Hz) = Tc
f
(ppm/K) x (T - T
o
)2 x
f
To
(MHz)
Operating temperature range
- 25 °C ... + 75 °C
Storage temperature range
- 30 °C ... + 85 °C
* ) f
To
is reference frequence
fc
at frequency inversion temperature (
T
o
)
Generated: Dunzow W.
Checked/Approved: Dr. Bert Wall