參數(shù)資料
型號: 7005
廠商: Aeroflex Inc.
英文描述: ACT7005/7006 Single Package Solution Dual Transceiver, Protocol, Subsystem
中文描述: ACT7005/7006單一封裝解決方案雙收發(fā)器,協(xié)議,子系統(tǒng)
文件頁數(shù): 12/29頁
文件大小: 452K
代理商: 7005
Aeroflex Circuit Technology
SCD7005 REV B 8/2/01
Plainview NY (516) 694-6700
12
described below are available and are essentially
independent. Any, all, or none may be selected.
Also, reporting of faults by the subsystem requires
that SSERR be latched (not pulsed) low until the
fault is cleared.
Resetting SSF and TF on Receipt of Valid
Commands
If ENABLE is selected and the other three option
lines are held high, then the Status Word Register
will be reset on receipt of any valid command with
the exception of Transmit Status and Transmit Last
Command. Note that in this mode, the TF will never
be seen in the Status Word, and the SSF will only be
seen if SSERR is latched low. Also note that the SSF
will not be seen in response to Transmit Status or
Transmit Last Command if the preceding Status
Word was clear, regardless of actions taken on the
SSERR line after the clear status transmission.
Status Register Update at Fault Occurrence
If STATUS UPDATE is selected (held low), then the
TF or SSF will appear in response to a Transmit
Status or Transmit Last Command issued as the first
command after the fault occurs. Any other command
(except as noted in the Preserving the BIT Word
section) will reset the TF and SSF. Repeated
Transmit Status or Transmit Last Command
immediately following the fault will continue to show
the TF and/or SSF in the Status Word. Note that this
behavior may not meet the "letter-of-the-spec" as
described in MIL-STD-1553B, but is considered the
"preferred" behavior by some users.
TF and SSF Reporting in the Next Status
Word – After the Fault
If NEXT STATUS is selected (held low), then the TF
or SSF will appear in response to the very next valid
command after the fault except for Transmit Status
or Transmit Last Command. The flag(s) will be reset
on receipt of any valid command following the status
transmission with the flag(s) set except for Transmit
Status, Transmit Last Command, or as noted in the
following section on Preserving the BIT Word.
Preserving the BIT Word
In order to preserve the Transmitter Timeout Flag,
Subsystem Handshake Failure, and Loop Test
Failure Bits in the BIT Word, it is necessary to select
BIT DECODE (hold it low). This will prevent resetting
those bits if the Transmit Bit Word Mode Command
immediately follows the fault or follows a Transmit
Last Command or Transmit Status immediately
following the fault. It will also prevent resetting the TF
and SSF Bits in the Status Word. Any other valid
commands will cause those BIT Word Bits and the
Status Word Bits to be reset.
相關(guān)PDF資料
PDF描述
7006 ACT7005/7006 Single Package Solution Dual Transceiver, Protocol, Subsystem
700B Power Module: Custom Dc-Dc Converter, 24 V to 97 V Adjustable Output(DC-DC轉(zhuǎn)換器,24V-97V可調(diào)輸出)
700SCFM 20SCFM
701011xxx AXIAL LEAD PRECISION WIREWOUND RESISTORS
70405xxx AXIAL LEAD PRECISION WIREWOUND RESISTORS
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
700-5 制造商:MICROSEMI 制造商全稱:Microsemi Corporation 功能描述:RECTIFIERS ASSEMBLIES THREE PHASE BRIDGES, 2.5 AMP, STANDARD AND FAST RECOVERY
70050 制造商:Acme Electric Corporation XXX 功能描述:TOROIDAL TRANSFORMER, Power Rating:15VA, Secondary Voltages:2 x 7V, Secondary Cu
700-500 制造商:未知廠家 制造商全稱:未知廠家 功能描述:PCB SHEARS 30CM
700-500 制造商:Mega Electronics Inc 功能描述:SHEAR PCB 30CM 制造商:Mega Electronics Inc 功能描述:SHEAR, PCB, 30CM 制造商:MEGA 功能描述:SHEAR, PCB, 30CM, Cutting Capacity Max:305mm, Aluminium Cutting Capacity:1.5mm, 制造商:MEGA 功能描述:SHEAR, PCB, 305MM, Cutting Capacity Max:305mm, Aluminum Cutting Capacity:1.5mm, External Depth:440mm, External Width:245mm, Cut Width Max:305mm , RoHS Compliant: NA
70050-002 制造商:FCI 功能描述:SET SCREW - Bulk
主站蜘蛛池模板: 夏邑县| 麻阳| 丁青县| 济南市| 华阴市| 阿坝| 屯昌县| 龙州县| 林芝县| 长垣县| 东城区| 连山| 克什克腾旗| 桑植县| 延庆县| 潜江市| 和静县| 凤城市| 永善县| 阿鲁科尔沁旗| 荔波县| 商都县| 烟台市| 三台县| 大同市| 中牟县| 大方县| 黄平县| 普安县| 崇州市| 新安县| 汤阴县| 铁岭县| 克拉玛依市| 怀柔区| 惠东县| 呼玛县| 新丰县| 福安市| 花莲市| 博兴县|