參數(shù)資料
型號(hào): AD7755ABRS
廠商: ANALOG DEVICES INC
元件分類(lèi): 模擬信號(hào)調(diào)理
英文描述: Energy Metering IC with Pulse Output
中文描述: SPECIALTY ANALOG CIRCUIT, PDSO24
封裝: SSOP-24
文件頁(yè)數(shù): 13/16頁(yè)
文件大?。?/td> 250K
代理商: AD7755ABRS
REV. B
AD7755
–13–
FREQUENCY
Hz
0
100
P
0.05
0.10
0
0.05
0.10
0.15
0.20
0.25
0.30
200
300
400
500
600
700
800
900 1000
Figure 28. Phase Error Between Channels (0 Hz to 1 kHz)
FREQUENCY
Hz
40
P
0.05
0.10
0
0.05
0.10
0.15
0.20
0.25
0.30
45
50
55
60
65
70
Figure 29. Phase Error Between Channels (40 Hz to 70 Hz)
DIGITAL-TO-FREQUENCY CONVERSION
As previously described, the digital output of the low-pass filter
after multiplication contains the real power information. How-
ever since this LPF is not an ideal “brick wall” filter implemen-
tation, the output signal also contains attenuated components
at the line frequency and its harmonics, i.e., cos(h
ω
t) where
h
= 1, 2, 3, . . . etc.
The magnitude response of the filter is given by:
|
H( )|
( /8 9
f
)
Hz
=
+
1
1
(5)
For a line frequency of 50 Hz this would give an attenuation of
the 2
ω
(100 Hz) component of approximately –22 dBs. The
dominating harmonic will be at twice the line frequency, i.e.,
cos (2
ω
t) and this is due to the instantaneous power signal.
Figure 30 shows the instantaneous real power signal at the output
of the CPF which still contains a significant amount of instanta-
neous power information, i.e., cos (2
ω
t). This signal is then
passed to the digital-to-frequency converter where it is integrated
(accumulated) over time in order to produce an output fre-
quency. This accumulation of the signal will suppress or average
out any non-dc components in the instantaneous real power
signal. The average value of a sinusoidal signal is zero. Hence
the frequency generated by the AD7755 is proportional to the
average real power. Figure 30 shows the digital-to-frequency
conversion for steady load conditions, i.e., constant voltage and
current.
2
V I
2
FREQUENCY
RAD/S
LPF
DIGITAL-TO-
FREQUENCY
F1
F2
DIGITAL-TO-
FREQUENCY
CF
INSTANTANEOUS REAL POWER SIGNAL
(FREQUENCY DOMAIN)
MULTIPLIER
TIME
FF1
FOUT
TIME
V
I
0
LPF TO EXTRACT
REAL POWER
(DC TERM)
cos(2 t)
ATTENUATED BY LPF
Figure 30. Real Power-to-Frequency Conversion
As can be seen in the diagram, the frequency output CF is seen
to vary over time, even under steady load conditions. This fre-
quency variation is primarily due to the cos (2
ω
t) component in
the instantaneous real power signal. The output frequency on
CF can be up to 2048 times higher than the frequency on F1
and F2. This higher output frequency is generated by accumu-
lating the instantaneous real power signal over a much shorter
time while converting it to a frequency. This shorter accumula-
tion period means less averaging of the cos (2
ω
t) component.
As a consequence, some of this instantaneous power signal passes
through the digital-to-frequency conversion. This will not be a
problem in the application. Where CF is used for calibration
purposes, the frequency should be averaged by the frequency
counter. This will remove any ripple. If CF is being used to
measure energy, e.g., in a microprocessor-based application, the
CF output should also be averaged to calculate power. Because
the outputs F1 and F2 operate at a much lower frequency, a lot
more averaging of the instantaneous real power signal is carried
out. The result is a greatly attenuated sinusoidal content and a
virtually ripple-free frequency output.
相關(guān)PDF資料
PDF描述
AD7755AAN Energy Metering IC with Pulse Output
AD7760 2.5 MSPS, 20-Bit ADC
AD7760BCP 2.5 MSPS, 20-Bit ADC
AD7760BSV 2.5 MSPS, 20-Bit ADC
AD7769 LC2MOS Analog I/O Port
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
AD7755AN 制造商:Rochester Electronics LLC 功能描述:ENERGY METERING IC WITH P - Bulk
AD7755ARS 制造商:Rochester Electronics LLC 功能描述:- Bulk
AD7756AN 制造商:Rochester Electronics LLC 功能描述:- Bulk
AD7756ARS 制造商:Rochester Electronics LLC 功能描述:- Bulk