欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: AD7755ABRS
廠商: ANALOG DEVICES INC
元件分類: 模擬信號調理
英文描述: Energy Metering IC with Pulse Output
中文描述: SPECIALTY ANALOG CIRCUIT, PDSO24
封裝: SSOP-24
文件頁數: 16/16頁
文件大?。?/td> 250K
代理商: AD7755ABRS
REV. B
AD7755
–16–
C
P
24-Lead Plastic DIP
(N-24)
24
1
12
13
PIN 1
1.275 (32.30)
1.125 (28.60)
0.280 (7.11)
0.240 (6.10)
0.195 (4.95)
0.115 (2.93)
0.015 (0.381)
0.008 (0.204)
0.325 (8.25)
0.300 (7.62)
SEATING
PLANE
0.060 (1.52)
0.015 (0.38)
0.210
(5.33)
MAX
0.022 (0.558)
0.014 (0.356)
0.200 (5.05)
0.125 (3.18)
0.150
(3.81)
MIN
0.100
(2.54)
BSC
0.070 (1.77)
0.045 (1.15)
OUTLINE DIMENSIONS
Dimensions shown in inches and (mm).
24
1
13
12
0.328 (8.33)
0.318 (8.08)
0.311 (7.9)
0.301 (7.64)
0.212 (5.38)
0.205 (5.207)
PIN 1
SEATING
PLANE
0.07 (1.78)
0.066 (1.67)
0.008 (0.203)
0.002 (0.050)
0.0256
(0.65)
BSC
0.078 (1.98)
0.068 (1.73)
0.015 (0.38)
0.010 (0.25)
0.009 (0.229)
0.005 (0.127)
0.037 (0.94)
0.022 (0.559)
8
°
0
°
24-Lead Shrink Small Outline Package
(RS-24)
Table VI. F1 and F2 Frequency with Half-Scale AC Inputs
Frequency on F1 and F2–
CH1 and CH2 Half-Scale AC Inputs
S1
S0
F
1–4
1.7
3.4
6.8
13.6
0
0
1
1
0
1
0
1
0.085 Hz
0.17 Hz
0.34 Hz
0.68 Hz
When selecting a suitable F
1–4
frequency for a meter design, the
frequency output at I
MAX
(maximum load) with a meter con-
stant of 100 imp/kWhr should be compared with Column 4 of
Table VI. The frequency that is closest in Table VI will deter-
mine the best choice of frequency (F
1–4
). For example, if a meter
with a maximum current of 25 A is being designed, the out-
put frequency on F1 and F2 with a meter constant of 100 imp/
kWhr is 0.153 Hz at 25 A and 220 V (from Table V). Looking
at Table VI, the closest frequency to 0.153 Hz in column four is
0.17 Hz. Therefore F
2
(3.4 Hz—see Table II) is selected for this
design.
Frequency Outputs
Figure 1 shows a timing diagram for the various frequency out-
puts. The outputs F1 and F2 are the low frequency outputs that
can be used to directly drive a stepper motor or electromechani-
cal impulse counter. The F1 and F2 outputs provide two alter-
nating low going pulses. The pulsewidth (t
1
) is set at 275 ms and
the time between the falling edges of F1 and F2 (t
3
) is approxi-
mately half the period of F1 (t
2
). If however the period of F1
and F2 falls below 550 ms (1.81 Hz) the pulsewidth of F1 and
F2 is set to half of their period. The maximum output frequen-
cies for F1 and F2 are shown in Table III.
The high frequency CF output is intended to be used for com-
munications and calibration purposes. CF produces a 90 ms-
wide active high pulse (t
4
) at a frequency proportional to active
power. The CF output frequencies are given in Table IV. As in
the case of F1 and F2, if the period of CF (t
5
) falls below 180 ms,
the CF pulsewidth is set to half the period. For example, if the CF
frequency is 20 Hz, the CF pulsewidth is 25 ms.
NOTE: When the high frequency mode is selected, (i.e., SCF =
0, S1 = S0 = 1) the CF pulsewidth is fixed at 18
μ
s. Therefore t
4
will always be 18
μ
s, regardless of output frequency on CF.
NO LOAD THRESHOLD
The AD7755 also includes a “no load threshold” and “start-up
current” feature that will eliminate any creep effects in the
meter. The AD7755 is designed to issue a minimum output
frequency on all modes except when SCF = 0 and S1 = S0 = 1.
The no-load detection threshold is disabled on this output mode
to accommodate specialized application of the AD7755. Any
load generating a frequency lower than this minimum frequency
will not cause a pulse to be issued on F1, F2 or CF. The mini-
mum output frequency is given as 0.0014% of the full-scale
output frequency for each of the F
1–4
frequency selections—see
Table II. For example, an energy meter with a meter constant
of 100 imp/kWhr on F1, F2 using F
2
(3.4 Hz), the maximum
output frequency at F1 or F2 would be 0.0014% of 3.4 Hz or
4.76
×
10
–5
Hz. This would be 3.05
×
10
–3
Hz at CF (64
×
F1 Hz).
In this example the no-load threshold would be equivalent to
1.7 W of load or a start-up current of 8 mA at 220 V. Compar-
ing this value to the IEC1036 specification which states that the
meter must start up with a load equal to or less than 0.4% Ib.
For a 5A (Ib) meter 0.4% of Ib is equivalent to 20 mA.
相關PDF資料
PDF描述
AD7755AAN Energy Metering IC with Pulse Output
AD7760 2.5 MSPS, 20-Bit ADC
AD7760BCP 2.5 MSPS, 20-Bit ADC
AD7760BSV 2.5 MSPS, 20-Bit ADC
AD7769 LC2MOS Analog I/O Port
相關代理商/技術參數
參數描述
AD7755AN 制造商:Rochester Electronics LLC 功能描述:ENERGY METERING IC WITH P - Bulk
AD7755ARS 制造商:Rochester Electronics LLC 功能描述:- Bulk
AD7756AN 制造商:Rochester Electronics LLC 功能描述:- Bulk
AD7756ARS 制造商:Rochester Electronics LLC 功能描述:- Bulk
AD775JN 制造商:Analog Devices 功能描述:ADC SGL PIPELINED 20MSPS 8BIT PARALLEL 24PDIP - Bulk 制造商:Rochester Electronics LLC 功能描述:8-BIT 20 MSPS, 60 MW SAMPLING A/D CONVERTER - Bulk
主站蜘蛛池模板: 京山县| 甘南县| 莱西市| 疏附县| 嘉义市| 南昌县| 铜山县| 宜春市| 平度市| 磐石市| 宽甸| 铜鼓县| 且末县| 黄梅县| 南平市| 车致| 五华县| 外汇| 孟津县| 河北区| 屏南县| 张掖市| 彰武县| 高唐县| 青川县| 南投市| 满洲里市| 南岸区| 临夏县| 剑河县| 延川县| 乌鲁木齐县| 昌平区| 平乡县| 南安市| 和林格尔县| 白河县| 小金县| 上高县| 琼结县| 中山市|