欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: AD8018ARU
廠商: ANALOG DEVICES INC
元件分類: 運動控制電子
英文描述: 5 V, Rail-to-Rail, High-Output Current, xDSL Line Drive Amplifier
中文描述: DUAL OP-AMP, 17000 uV OFFSET-MAX, PDSO14
封裝: PLASTIC, TSSOP-14
文件頁數: 9/19頁
文件大小: 339K
代理商: AD8018ARU
REV. 0
AD8018
–9–
Table I. Resistor Selection Guide
Gain
R
F
( )
681
1 k
750
511
340
230
R
G
( )
681
750
256
113
59
1
+1
+2
+3
+4
+5
POWER-DOWN FEATURES
Two digitally programmable logic pins, PWDN1 and PWDN0,
are available on the TSSOP-14 package to select among three
different modes of operation, full power, standby and shutdown.
The DGND pin is the logic ground reference. The logic thresh-
old voltage is established 1 V above DGND. In a typical 5 V
single-supply application, the DGND pin is connected to analog
ground. If PWDN1, PWDN0, and DGND are left unconnected,
the AD8018 will operate at full power.
Table II. Power-Down Features and Truth Table
Supply
Current
Output
Impedance
PWDN0
PWDN1
State
High
Low
High
Low
High
High
Low
Low
Full Power
Standby
Standby
Disabled
18 mA
9 mA
9 mA
300
μ
A
Low
Low
Low
High
POWER SUPPLY AND DECOUPLING
The AD8018 can be powered with a good quality (i.e., low-noise)
supply anywhere in the range from 3.3 V to 8 V. However, in
order to optimize the ADSL upstream drive capability to +13 dBm
and maintain the best Spurious Free Dynamic Range (SFDR),
the AD8018 circuit should be supplied with a well regulated 5 V
supply. The 5 V supplied at the USB port may be poorly regu-
lated. Improving the quality of the 5 V supply will optimize the
performance of the AD8018 in a USB-supplied CPE ADSL
modem. This can be accomplished through the use of a step-up
dc-to-dc converter or switching power supply followed by a low
dropout (LDO) regulator such as the ADP3331 (see Figure 6).
Setting R1 to be 953 k
and R2 to be 301 k
will result in a
V
OUT
of 5 V.
Careful attention must be paid to decoupling the power supply
pins at the output of the dc-to-dc converter, the output of the
LDO regulator and the supply pins of the AD8018. High-quality
capacitors with low equivalent series resistance (ESR) such as
multilayer ceramic capacitors (MLCCs) should be used to mini-
mize supply voltage ripple and power dissipation. A large, usually
tantalum, 10
μ
F to 47
μ
F capacitor located in proximity to the
AD8018 is required to provide good decoupling for lower fre-
quency signals. In addition, 0.1
μ
F MLCC decoupling capacitors
should be located as close to each of the power supply pins as is
physically possible, no more than 1/8 inch away. An additional
large (4.7
μ
F to 10
μ
F) tantalum capacitor should be placed on the
board near the supply terminals to supply current for fast, large-
signal changes at the AD8018 outputs.
ADP3331
C1
0.47 F
V
IN
ON
OFF
V
OUT
E
OUT
C2
0.47 F
R3
330k
IN
SD
GND
OUT
FB
ERR
R1
953k
R2
301k
Figure 6. ADP3331 LDO
METHOD FOR GENERATING A MIDSUPPLY VOLTAGE
To operate an amplifier on a single voltage supply, a voltage
midway between the supply and ground must be generated to
properly bias the inputs and the outputs.
A voltage divider can be created with two equal value resistors
(Figure 7). There is a trade-off between the power consumed by
the divider and the voltage drop across these resistors due to the
positive input bias currents. Selecting 2.5 k
for R1 and R2 will
create a voltage divider that draws only 1 mA from a 5 V supply.
The voltage generated with this topology can vary due to the
temperature coefficient (TC) of resistance. Resistors that are
closely matched and have a low TC will minimize variations in
the voltage reference due to temperature. One should also be
sure to use a decoupling capacitor (0.1
μ
F) at the node where
V
REF
is generated.
5V
R1
2.5k
R2
2.5k
V
REF
0.1 F
Figure 7. Midsupply Reference
DIFFERENTIAL TESTING
The test circuit shown in TPC 13 is used for measuring the dif-
ferential distortion of the AD8018. A single-ended test signal is
applied to the inverting input of the AD8138 differential driver
with the noninverting input grounded. Applying the differential
output of the AD8138 through 100
resistors serves to isolate
the inputs of the AD8018 differential driver and provide a well-
balanced low-distortion input signal. The differential load (R
L
)
of the AD8018 can be set to the equivalent of the line imped-
ance reflected through a transformer. The AD9632 converts
the differential output voltage back to a single-ended signal.
The differential-to- single-ended converter using the AD9632
has an attenuation of
26 dB and is wired with precision resis-
tors to optimize the balance of differential input signal. The
resulting smaller output signal can be easily measured using a
50
spectrum analyzer.
相關PDF資料
PDF描述
AD8018AR-REEL 5 V, Rail-to-Rail, High-Output Current, xDSL Line Drive Amplifier
AD8019ARU-EVAL DSL Line Driver with Power-Down
AD8019ARU-REEL DSL Line Driver with Power-Down
AD8019 DSL Line Driver with Power-Down
AD8019AR DSL Line Driver with Power-Down
相關代理商/技術參數
參數描述
AD8018ARU-EVAL 功能描述:BOARD EVAL FOR AD8018 RoHS:否 類別:編程器,開發系統 >> 評估演示板和套件 系列:- 標準包裝:1 系列:- 主要目的:電信,線路接口單元(LIU) 嵌入式:- 已用 IC / 零件:IDT82V2081 主要屬性:T1/J1/E1 LIU 次要屬性:- 已供物品:板,電源,線纜,CD 其它名稱:82EBV2081
AD8018ARU-REEL 制造商:Analog Devices 功能描述:ADSL Driver Dual 14-Pin TSSOP T/R 制造商:Rochester Electronics LLC 功能描述:TSSOP DUAL+5V HISPD HIOUTPUTCURRENT AMP - Tape and Reel
AD8018ARU-REEL7 制造商:Analog Devices 功能描述:ADSL Driver Dual 14-Pin TSSOP T/R 制造商:Rochester Electronics LLC 功能描述:TSSOP DUAL+5V HISPD HIOUTPUTCURRENT AMP - Tape and Reel
AD8018ARUZ 功能描述:IC LINE DRIVER XDSL R-R 14TSSOP RoHS:是 類別:集成電路 (IC) >> 接口 - 驅動器,接收器,收發器 系列:- 標準包裝:1 系列:- 類型:線路收發器 驅動器/接收器數:5/3 規程:RS232 電源電壓:3 V ~ 5.5 V 安裝類型:表面貼裝 封裝/外殼:28-SOIC(0.295",7.50mm 寬) 供應商設備封裝:28-SOIC 包裝:Digi-Reel® 產品目錄頁面:918 (CN2011-ZH PDF) 其它名稱:296-25096-6
AD8018ARUZ-REEL 功能描述:IC LINE DRIVER XDSL R-R 14TSSOP RoHS:是 類別:集成電路 (IC) >> 接口 - 驅動器,接收器,收發器 系列:- 標準包裝:27 系列:- 類型:收發器 驅動器/接收器數:3/3 規程:RS232,RS485 電源電壓:4.75 V ~ 5.25 V 安裝類型:表面貼裝 封裝/外殼:28-SOIC(0.295",7.50mm 寬) 供應商設備封裝:28-SOIC 包裝:管件
主站蜘蛛池模板: 溧水县| 灌南县| 和政县| 宁波市| 祁连县| 尚义县| 蒙城县| 庄河市| 宜兰县| 和平区| 石渠县| 登封市| 鞍山市| 南澳县| 林西县| 江油市| 青阳县| 石门县| 河北省| 获嘉县| 楚雄市| 陈巴尔虎旗| 南京市| 白水县| 涿州市| 乳山市| 日喀则市| 霍邱县| 岑溪市| 正安县| 永德县| 甘肃省| 武鸣县| 崇阳县| 焦作市| 包头市| 克拉玛依市| 绩溪县| 方山县| 永城市| 临西县|