欧美成人免费电影,国产欧美一区二区三区精品酒店,精品国产a毛片,色网在线免费观看

參數資料
型號: ADM1024ARU
廠商: ANALOG DEVICES INC
元件分類: 電源管理
英文描述: Circular Connector; No. of Contacts:8; Series:LJT06R; Body Material:Aluminum; Connecting Termination:Crimp; Connector Shell Size:17; Circular Contact Gender:Pin; Circular Shell Style:Straight Plug; Insert Arrangement:17-8
中文描述: 9-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO24
封裝: MO-153AD, TSSOP-24
文件頁數: 13/28頁
文件大?。?/td> 285K
代理商: ADM1024ARU
ADM1024
–13–
REV. 0
10MIL
10MIL
10MIL
10MIL
10MIL
10MIL
10MIL
GND
D+
D
GND
Figure 15. Arrangement of Signal Tracks
4. Try to minimize the number of copper/solder joints, which
can cause thermocouple effects. Where copper/solder joints
are used, make sure that they are in both the D+ and D–
path and at the same temperature.
Thermocouple effects should not be a major problem as 1
°
C
corresponds to about 240
μ
V, and thermocouple voltages are
about 3
μ
V/
o
C of temperature difference. Unless there are
two thermocouples with a big temperature differential between
them, thermocouple voltages should be much less than 200 mV.
5. Place 0.1
μ
F bypass and 2200 pF input filter capacitors close
to the ADM1024.
6. If the distance to the remote sensor is more than 8 inches, the
use of twisted pair cable is recommended. This will work up
to about 6 feet to 12 feet.
7. For really long distances (up to 100 feet) use shielded twisted
pair such as Belden #8451 microphone cable. Connect the
twisted pair to D+ and D– and the shield to GND close to the
ADM1024. Leave the remote end of the shield unconnected
to avoid ground loops.
Because the measurement technique uses switched current
sources, excessive cable and/or filter capacitance can affect the
measurement. When using long cables, the filter capacitor may
be reduced or removed.
Cable resistance can also introduce errors. One
series resis-
tance introduces about 0.5
°
C error.
LIMIT VALUES
Limit values for analog measurements are stored in the appro-
priate limit registers. In the case of voltage measurements, high
and low limits can be stored so that an interrupt request will be
generated if the measured value goes above or below acceptable
values. In the case of temperature, a Hot Temperature or High
Limit can be programmed, and a Hot Temperature Hyster-
esis or Low Limit, which will usually be some degrees lower.
This can be useful as it allows the system to be shut down when
the hot limit is exceeded, and restarted automatically when it has
cooled down to a safe temperature.
MONITORING CYCLE TIME
The monitoring cycle begins when a one is written to the
Start Bit (Bit 0), and a zero to the
INT
_Clear Bit (Bit 3) of
the Configuration Register.
INT
_Enable (Bit 1) should be set
to one to enable the
INT
output. The ADC measures each analog
input in turn, as each measurement is completed the result is
automatically stored in the appropriate value register. This “round-
robin” monitoring cycle continues until it is disabled by writing
a 0 to Bit 0 of the Configuration Register.
As the ADC will normally be left to free-run in this manner, the
time taken to monitor all the analog inputs will normally not be
of interest, as the most recently measured value of any input can
be read out at any time.
For applications where the monitoring cycle time is important,
it can be calculated as follows:
m
×
t
1
×
n
×
t
2
where:
m
is the number of inputs configured as analog inputs, plus the
internal V
CC
measurement and internal temperature sensor.
t
1
is the time taken for an analog input conversion, nominally
755
μ
s.
n
is the number of inputs configured as external temperature
inputs.
t
2
is the time taken for a temperature conversion, nominally
33.24 ms.
This rapid sampling of the analog inputs ensures a quick response
in the event of any input going out of limits, unlike other moni-
toring chips that employ slower ADCs.
FAN MONITORING CYCLE TIME
When a monitoring cycle is started, monitoring of the fan speed
inputs begins at the same time as monitoring of the analog inputs.
However, the two monitoring cycles are not synchronized in any
way. The monitoring cycle time for the fan inputs is dependent
on fan speed and is much slower than for the analog inputs. For
more details see Fan Speed Measurement section.
INPUT SAFETY
Scaling of the analog inputs is performed on chip, so external
attenuators are normally not required. However, since the power
supply voltages will appear directly at the pins, its is advisable to
add small external resistors in series with the supply traces to the
chip to prevent damaging the traces or power supplies should a
accidental short such as a probe connect two power supplies
together.
As the resistors will form part of the input attenuators, they will
affect the accuracy of the analog measurement if their value is
too high. The analog input channels are calibrated assuming an
external series resistor of 500
, and the accuracy will remain
within specification for any value from zero to 1 k
, so a stan-
dard 510
resistor is suitable.
The worst such accident would be connecting –12 V to +12 V—
a total of 24 V difference, with the series resistors this would draw
a maximum current of approximately 24 mA.
ANALOG OUTPUT
The ADM1024 has a single analog output from a unsigned 8-bit
DAC which produces 0 V–2.5 V. The analog output register
defaults to FF during power-on reset, which produces maximum
fan speed. The analog output may be amplified and buffered
with external circuitry such as an op amp and transistor to provide
fan speed control.
相關PDF資料
PDF描述
ADM1025 Circular Connector; No. of Contacts:8; Series:LJT06R; Body Material:Aluminum; Connecting Termination:Crimp; Connector Shell Size:17; Circular Contact Gender:Pin; Circular Shell Style:Straight Plug; Insert Arrangement:17-8
ADM1025A Circular Connector; No. of Contacts:8; Series:LJT06R; Body Material:Aluminum; Connecting Termination:Crimp; Connector Shell Size:17; Circular Contact Gender:Socket; Circular Shell Style:Straight Plug; Insert Arrangement:17-8
ADM1025AARQ Low-Cost PC Hardware Monitor ASIC
ADM1025ARQ Low-Cost PC Hardware Monitor ASIC
ADM1026 Complete Thermal and System Management Controller
相關代理商/技術參數
參數描述
ADM1024ARU-REEL 功能描述:IC MONITOR SYS TEMP/VOLT 24TSSOP RoHS:否 類別:集成電路 (IC) >> 接口 - 專用 系列:- 標準包裝:3,000 系列:- 應用:PDA,便攜式音頻/視頻,智能電話 接口:I²C,2 線串口 電源電壓:1.65 V ~ 3.6 V 封裝/外殼:24-WQFN 裸露焊盤 供應商設備封裝:24-QFN 裸露焊盤(4x4) 包裝:帶卷 (TR) 安裝類型:表面貼裝 產品目錄頁面:1015 (CN2011-ZH PDF) 其它名稱:296-25223-2
ADM1024ARUZ 功能描述:馬達/運動/點火控制器和驅動器 THERMAL & VOLT MONITOR IC RoHS:否 制造商:STMicroelectronics 產品:Stepper Motor Controllers / Drivers 類型:2 Phase Stepper Motor Driver 工作電源電壓:8 V to 45 V 電源電流:0.5 mA 工作溫度:- 25 C to + 125 C 安裝風格:SMD/SMT 封裝 / 箱體:HTSSOP-28 封裝:Tube
ADM1024ARUZ-R7 功能描述:板上安裝溫度傳感器 +/-2 C / +/-3 C Digital RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
ADM1024ARUZ-REEL 功能描述:板上安裝溫度傳感器 THERMAL & VOLT MONITOR IC RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
ADM1024ARUZ-REEL7 功能描述:IC MONITOR SYS TEMP/VOLT 24TSSOP RoHS:是 類別:集成電路 (IC) >> 接口 - 專用 系列:- 標準包裝:3,000 系列:- 應用:PDA,便攜式音頻/視頻,智能電話 接口:I²C,2 線串口 電源電壓:1.65 V ~ 3.6 V 封裝/外殼:24-WQFN 裸露焊盤 供應商設備封裝:24-QFN 裸露焊盤(4x4) 包裝:帶卷 (TR) 安裝類型:表面貼裝 產品目錄頁面:1015 (CN2011-ZH PDF) 其它名稱:296-25223-2
主站蜘蛛池模板: 尼木县| 大邑县| 道孚县| 那坡县| 宽城| 雷波县| 聂荣县| 习水县| 获嘉县| 客服| 射洪县| 于都县| 收藏| 象山县| 开远市| 永康市| 东兰县| 青铜峡市| 宁德市| 揭西县| 金乡县| 丹凤县| 高淳县| 沂源县| 四会市| 牟定县| 新津县| 拉孜县| 琼结县| 武冈市| 柳江县| 仙居县| 阿拉善盟| 辽阳县| 平乡县| 墨竹工卡县| 孝昌县| 静安区| 南投市| 孝感市| 凌源市|