參數資料
型號: MAX6581TG9A+
廠商: Maxim Integrated
文件頁數: 17/27頁
文件大小: 1212K
描述: IC TEMP SENSOR 8-CH PREC 24-TQFN
產品培訓模塊: Lead (SnPb) Finish for COTS
Obsolescence Mitigation Program
標準包裝: 75
功能: 溫度監控器
傳感器類型: 內部和外部
感應溫度: -64°C ~ 150°C
精確度: ±3°C 本地(最大),±2.5°C 遠程(最大)
輸出類型: I²C?/SMBus?
輸出警報:
輸出風扇:
電源電壓: 3 V ~ 3.6 V
工作溫度: -40°C ~ 125°C
安裝類型: 表面貼裝
封裝/外殼: 24-WFQFN 裸露焊盤
供應商設備封裝: 24-TQFN-EP(4x4)
包裝: 管件
  17
Maxim Integrated
?癈 Accurate 8-Channel Temperature Sensor
MAX6581
Status Register Functions
There are four status registers (see Tables 710). The
ALERT High Status register indicates whether a mea-
sured local or remote temperature has exceeded the
associated threshold limit set in an ALERT High Limit
register. The OVERT Status register indicates whether
a measured temperature has exceeded the associated
threshold limit set in an OVERT High Limit register. The
Diode Fault Status register indicates whether there is a
diode fault (open or short) in any of the remote-sensing
channels. The ALERT Low Status register indicates
whether the measured temperature has fallen below the
threshold limit set in the ALERT Low Limits register for
the local or remote-sensing diodes.
Bits in the alert status registers are cleared by a success-
ful read, but set again after the next conversion unless
the fault is corrected, either by a drop in the measured
temperature or a change in the threshold temperature.
The ALERT interrupt output follows the status flag bit.
Once the ALERT output is asserted, it can be deasserted
by either reading the ALERT High Status register or by
successfully responding to an alert response address. In
both cases, the alert is cleared even if the fault condition
exists, but the ALERT output reasserts at the end of the
next conversion.
The bits indicating OVERT faults clear only when the
measured temperature drops below the temperature
threshold minus the hysteresis value (4NC), or when the
trip temperature is set to a value at least 4NC above the
current temperature.
Table 7. ALERT High Status Register (44h)
BIT
NAME
POR
STATE
FUNCTION
7 (MSB)
Remote ALERT
High 7
0
Channel 7 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 7
remote-diode temperature exceeds the programmed temperature threshold limit in the
Remote 7 ALERT High Limit register.
6
Local ALERT
High
0
Local Channel High-Alert Bit. This bit is set to logic 1 when the local temperature
exceeds the temperature threshold limit in the Local ALERT High Limit register.
5
Remote ALERT
High 6
0
Channel 6 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 6
remote-diode temperature exceeds the programmed temperature threshold limit in the
Remote 6 ALERT High Limit register.
4
Remote ALERT
High 5
0
Channel 5 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 5
remote-diode temperature exceeds the programmed temperature threshold limit in the
Remote 5 ALERT High Limit register.
3
Remote ALERT
High 4
0
Channel 4 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 4
remote-diode temperature exceeds the programmed temperature threshold limit in the
Remote 4 ALERT High Limit register.
2
Remote ALERT
High 3
0
Channel 3 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 3
remote-diode temperature exceeds the programmed temperature threshold limit in the
Remote 3 ALERT High Limit register.
1
Remote ALERT
High 2
0
Channel 2 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 2
remote-diode temperature exceeds the programmed temperature threshold limit in the
Remote 2 ALERT High Limit register.
0
Remote ALERT
High 1
0
Channel 1 Remote-Diode High-Alert Bit. This bit is set to logic 1 when the channel 1
remote-diode temperature exceeds the programmed temperature threshold limit in the
Remote 1 ALERT High Limit register.
相關PDF資料
PDF描述
MAX6602UE9A+T IC TEMP MONITOR 5CH 16-TSSOP
MAX6604ATA+TW IC TEMP SENSOR DDR MEMORY 8TDFN
MAX6616AEG+T IC TEMP MON FAN CNTRL 24QSOP
MAX6622UE9A+T IC PREC TEMP MONITOR 5CH 16TSSOP
MAX6626RMTT+T IC TEMP SENSOR I2C 6-TDFN
相關代理商/技術參數
參數描述
MAX6581TG9A+ 功能描述:板上安裝溫度傳感器 1C Accurate 8Ch Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX6581TG9A+T 功能描述:板上安裝溫度傳感器 1C Accurate 8Ch Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX6581TG9C+ 功能描述:板上安裝溫度傳感器 1C Accurate 8Ch Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX6581TG9C+T 功能描述:板上安裝溫度傳感器 1C Accurate 8Ch Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor
MAX6581TG9E+ 功能描述:板上安裝溫度傳感器 1C Accurate 8Ch Temperature Sensor RoHS:否 制造商:Omron Electronics 輸出類型:Digital 配置: 準確性:+/- 1.5 C, +/- 3 C 溫度閾值: 數字輸出 - 總線接口:2-Wire, I2C, SMBus 電源電壓-最大:5.5 V 電源電壓-最小:4.5 V 最大工作溫度:+ 50 C 最小工作溫度:0 C 關閉: 安裝風格: 封裝 / 箱體: 設備功能:Temperature and Humidity Sensor