SLOU186F – AUGUST 2006 – REVISED AUGUST 2010
the RF and receivers are switched ON. When this command is received, the reader observes the digitized
receiver output. If more than two edges are observed in 100 ms, the window comparator voltage is
increased. The procedure is repeated until the number of edges (changes of logical state) of the digitized
reception signal is less than 2 (in 100 ms). The command can reduce the input sensitivity in 5-dB
increments up to 15 dB. This command ensures better operation in a noisy environment.
The gain setting is reset to maximum gain at EN = 0, POR = 1.
5.4.9
Test External RF (RSSI at RX input with TX OFF)
This command can be used in active mode when the RF receiver is switched ON, and the RF output is
switched OFF (bit B1=1 in the chip status register, rec-on. See Table 5-9). The level of the RF signal
received on the antenna is measured and displayed in the RSSI levels register. The relation between the
3-bit code and the external RF field strength [A/m] must be determined by calculation or by experiments
for each antenna design. The antenna Q and connection to the RF input influence the result. The nominal
relation between the RF peak-to-peak voltage at the receiver inputs and its corresponding RSSI level is
presented as follows.
Receiver Input [mVPP]
40
60
80
100
140
180
300
RSSI level
1
2
3
4
5
6
7
If the direct command test RF internal or test RF external is used immediately after activation, it should be
preceded with a command enable RX to activate the RX section. For proper execution of the test RF
commands, the RX section must be enabled. This happens automatically when a data exchange between
the reader and the tag is done, or by sending a direct command enable RX.
5.4.10 Test Internal RF (RSSI at RX input with TX ON)
This command measures the level of the RF carrier at the receive inputs. Its operating range is between
300 mVp and 2.1 Vp with a step size of 300 mV. The two values are displayed in the RSSI levels register.
The command is intended for diagnostic purposes to set the correct RX_IN levels. The optimum RX_IN
input level is approximately 1.6 Vp, or an RSSI level of 5 or 6. The nominal relationship between the input
RF peak level and the RSSI code is presented as follows.
Receiver Input [mVPp]
300
600
900
1200
1500
1800
2100
RSSI Level
1
2
3
4
5
6
7
5.4.11 Block Receiver
The block receiver command puts the digital part of receiver (bit decoder and framer) in reset mode. This
is useful in an extremely noisy environment, where the noise level could otherwise cause a constant
switching of the sub-carrier input of the digital part of the receiver. The receiver (if not in reset) would try to
catch a SOF signal, and if the noise pattern matched the SOF pattern, an interrupt would be generated,
falsely signaling the start of an RX operation. A constant flow of interrupt requests can be a problem for
the external system (MCU), so the external system can stop this by putting the receive decoders in reset
mode. The reset mode can be terminated in two ways. The external system can send the enable receiver
command. The reset mode is also automatically terminated at the end of a TX operation. The receiver can
stay in reset after end of TX if the RX wait time register (address 08) is set. In this case, the receiver is
enabled at the end of the wait time following the transmit operation.
5.4.12 Enable Receiver
This command clears the reset mode in the digital part of the receiver if the reset mode was entered by
the block receiver command.
Copyright 2006–2010, Texas Instruments Incorporated
System Description
35
Product Folder Link(s): TRF7960 TRF7961
相關PDF資料
PDF描述
TRF7960RHBT SPECIALTY CONSUMER CIRCUIT, PQCC32
TRF7961RHBR SPECIALTY CONSUMER CIRCUIT, PQCC32
TRF7961RHBT SPECIALTY CONSUMER CIRCUIT, PQCC32
TS(X)8387MFDSSC/SMD 1-CH 8-BIT PROPRIETARY METHOD ADC, PARALLEL ACCESS, CQFP68
TS(X)8387MF_ 1-CH 8-BIT PROPRIETARY METHOD ADC, PARALLEL ACCESS, CQFP68
相關代理商/技術參數(shù)
參數(shù)描述
TRF7960RHBRG4 功能描述:RFID應答器 Multi-Std Fully Int 13.56MHz RFID AFE RoHS:否 制造商:Murata 存儲容量:512 bit 工作溫度范圍:- 40 C to + 85 C 安裝風格:SMD/SMT 封裝 / 箱體: 封裝:Reel
TRF7960RHBT 功能描述:RFID應答器 Mulit-Standard High Freq RFid Reader RoHS:否 制造商:Murata 存儲容量:512 bit 工作溫度范圍:- 40 C to + 85 C 安裝風格:SMD/SMT 封裝 / 箱體: 封裝:Reel
TRF7960RHBT 制造商:Texas Instruments 功能描述:RFID Reader IC 制造商:Texas Instruments 功能描述:IC, RFID READER, 13.56MHZ, QFN-32
TRF7960RHBTG4 功能描述:RFID應答器 Mulit-Standard High Freq RFID Read/Writ RoHS:否 制造商:Murata 存儲容量:512 bit 工作溫度范圍:- 40 C to + 85 C 安裝風格:SMD/SMT 封裝 / 箱體: 封裝:Reel
TRF7960TB 功能描述:射頻識別變換器工具 TRF7960 Target Board RoHS:否 制造商:Olimex Ltd. 產(chǎn)品:RFID Readers 用于:ISO15693
主站蜘蛛池模板: 大同县| 定远县| 兰考县| 长葛市| 咸宁市| 梨树县| 安溪县| 肥乡县| 双城市| 新竹县| 太白县| 普兰店市| 分宜县| 固镇县| 嘉定区| 武邑县| 仙游县| 利辛县| 崇仁县| 杨浦区| 凭祥市| 柏乡县| 大田县| 遂宁市| 汶上县| 揭东县| 宁阳县| 芜湖市| 专栏| 同德县| 绥德县| 隆子县| 原平市| 教育| 丹东市| 肥乡县| 炎陵县| 汉源县| 鄢陵县| 石渠县| 东乌珠穆沁旗|