LC89057W-VF4-E
No. 7202-40/61
CCB address: 0xE8; Command address: 2; Demodulation function: Master clock setting
DI7
DI6
DI5
DI4
DI3
DI2
DI1
DI0
0
1
0
CAU
CAL
DI15
DI14
DI13
DI12
DI11
DI10
DI9
DI8
AMPOPR1
AMPOPR0
EXSYNC
PLLOPR
XMSEL1
XMSEL0
XINSEL
PLLSEL
PLL lock frequency setting
0: 512fs (fs
≤ 96kHz commend) (initial value)
1: 256fs
XINSEL
XIN input frequency setting
0: 12.288MHz (initial value)
1: 24.576MHz
XMSEL [1:0]
XMCK output frequency setting
00: 1/1 of XIN input frequency (initial value)
01: 1/2 of XIN input frequency
10: Reserved
11: Muted
PLLOPR
PLL (VCO) operation setting
0: Operate (initial value)
1: Stop
EXSYNC
PLL unused demodulation function (external synchronization function) setting
0: PLL usage normal operation (initial value)
1: PLL unused external synchronization operation (supply 256fs clock to TMCK)
AMPOPR [1:0]
Oscillation amplifier operation setting
00: Automatic stopping of oscillation amplifier during PLL lock (initial value)
01: Normal continuous operation
10: Reserved
11: Stop
If the PLL is stopped with PLLOPR while the PLL is locked, the output clocks are all muted and this muted status
continues even if the PLL becomes unlocked.
If the permanent continuous operation setting is performed with AMPOPR0,1 while the PLL is locked, RERR goes
to into error status once. However, the RERR status can be set to be maintained if a setting so that no error is output
according to the PLL status even if the sampling frequency changes with FSERR is performed.
When the oscillation amplifier automatic stop mode is set with AMPOPR0,1, if the input sampling frequency
changes within the capture range of the PLL and no lock error occurs, sampling frequency calculation is not
performed in the oscillation amplifier stop status, so that the input data sampling frequency and the fs calculation
result may differ. However, if the channel status sampling frequency information is rewritten together with input
data changes, this information is reflected to the error flag and fs calculation of the input data is performed. Since
the oscillation amplifier permanent continuous operation setting is performed by permanent fs calculation, sampling
frequency changes are always reflected to the error flag.