71M6543F/H and 71M6543G/GH Data Sheet
v1.2
2008–2011 Teridian Semiconductor Corporation
125
The CE pulse generator can be controlled by either the MPU (external) or CE (internal) variables. Control is by
the MPU if the EXT_PULSE bit = 1 (CE RAM 0x20[5]). In this case, the MPU controls the pulse rate (external
pulse generation) by placing values into APULSEW and APULSER (CE RAM 0x45 and 0x49). By setting
EXT_PULSE = 0, the CE controls the pulse rate based on WSUM_X (CE RAM 0x84) and VARSUM_X (CE
RAM 0x88).
The 71M6543 Demo Code creep function halts both internal and external pulse generation.
Table 79: Sag Threshold, Phase Measurement, and Gain Adjust Control
CE
Address
Name
Default
Description
0x24
SAG_THR
2.39*10
7
The voltage threshold for sag warnings. The default value is
equivalent to 80 V RMS if VMAX = 600 V.
0x40
GAIN_ADJ0
16384
The assignments of these gain adjustments depends on the
The default value of 16384 corresponds to unity gain.
0x41
GAIN_ADJ1
16384
0x42
GAIN_ADJ2
16384
0x43
GAIN_ADJ3
16384
0x44
GAIN_ADJ4
16384
5.4.8
CE Transfer Variables
When the MPU receives the XFER_BUSY interrupt, it knows that fresh data is available in the transfer
variables. CE transfer variables are modified during the CE code pass that ends with an XFER_BUSY
interrupt. They remain constant throughout each accumulation interval. In this data sheet, the names of
CE transfer variables always end with _X. The transfer variables can be categorized as:
Fundamental energy measurement variables
Instantaneous (RMS) values
Other measurement parameters
Fundamental Energy Measurement Variables
Table 80 describes each transfer variable for fundamental energy measurement. All variables are signed
32-bit integers. Accumulated variables such as WSUM are internally scaled so they have at least 2x
margin before overflow when the integration time is one second. Additionally, the hardware does not permit
output values to fold back upon overflow.
Table 80: CE Transfer Variables (with Shunts)
CE
Address
Name
Description
Configuration
0x84
WSUM_X
The signed sum: W0SUM_X+W1SUM_X+W2SUM_X.
0x85
W0SUM_X
The sum of Wh samples from each wattmeter
element.
LSBW = 7.7562*10
-13 VMAX * IMAX Wh.
0x86
W1SUM_X
0x87
W2SUM_X
0x88
VARSUM_X
The signed sum:
VAR0SUM_X+VAR1SUM_X+VAR2SUM_X.
0x89
VAR0SUM_X
The sum of VARh samples from each wattmeter
element.
LSBW = 7.7562*10
-13 VMAX * IMAX VARh.
0x8A
VAR1SUM_X
0x8B
VAR2SUM_X
相關PDF資料
PDF描述
71M6543H-IGT/F SPECIALTY ANALOG CIRCUIT, PQFP100
71M6543G-IGTR/F SPECIALTY ANALOG CIRCUIT, PQFP100
71M6543GH-IGTR/F SPECIALTY ANALOG CIRCUIT, PQFP100
71M6543GH-IGT/F SPECIALTY ANALOG CIRCUIT, PQFP100
71M6543G-IGT/F SPECIALTY ANALOG CIRCUIT, PQFP100
相關代理商/技術參數
參數描述
71M6543FT-IGT/F 制造商:Maxim Integrated Products 功能描述:ENERGY METER ICS - Rail/Tube
71M6543FT-IGTR/F 制造商:Maxim Integrated Products 功能描述:3-PHASE SOC, 64KB FLASH, PRES TEMP SENSOR - Tape and Reel
71M6543G 制造商:MAXIM 制造商全稱:Maxim Integrated Products 功能描述:Selectable Gain of 1 or 8 for One Current Energy Meter ICs Metrology Compensation
71M6543GH 制造商:未知廠家 制造商全稱:未知廠家 功能描述:電表IC
71M6543GHT-IGT/F 制造商:Maxim Integrated Products 功能描述:3-PHASE, 128KB, PRES TEMP SENSOR, HI PREC - Bulk
主站蜘蛛池模板: 东山县| 太原市| 泌阳县| 张北县| 巴东县| 沾益县| 金秀| 连州市| 应城市| 舒城县| 偏关县| 社旗县| 高邑县| 陇南市| 象州县| 辽中县| 天津市| 鲁甸县| 唐海县| 天台县| 阿勒泰市| 平阳县| 水城县| 台中市| 岳阳市| 桐梓县| 陕西省| 垣曲县| 偏关县| 富蕴县| 屯门区| 滦平县| 会宁县| 延安市| 霍城县| 罗江县| 张家界市| 汉寿县| 柯坪县| 噶尔县| 从江县|