7.4
Finding the reference position
Q: How do I find a reference position?
A: The recommended way is to use the RunInit command. Two motions are specified through RunInit.
The first motion is to reach the mechanical stop. Its target position should be specified far away
enough so that the mechanical stop will be reached from any possible starting position. There is no
internal stall detection so that at the end of the first motion the step motor will bounce against the
mechanical stop loosing steps until the internal target position is reached. The second motion then can
be used either to drive in the opposite direction out of the mechanical stop right into the reference
position which is a known number of steps away from the mechanical stop. Or the second motion can
slowly drive a few steps in the same direction against the mechanical stop to compensate for the
bouncing of the faster first motion and stop as close to the mechanical stop as possible.
Q: Can the SWI input help in finding a reference position?
Not directly. The current state of the SWI input is reflected by the ESW flag which can only be polled
using the command GetFullStatus1. The SWI input resp. the ESW flag have neither influence on any
internal state machine nor on command processing. The recommended way to find a reference
position is to use the RunInit command. Alternatively one could initiate a long distance motion at very
low speed using SetPosition and then poll ESW as frequently as possible to be able to stop the motion
using HardStop right in the moment the switch position is reached. Then one would reset the internal
position counters ActPos and TagPos using the ResetPosition command.
Q: What is the logic of the ESW flag?
A: The ESW flag reflects the state of the SWI input. ESW is set to one if SWI is high or low, i.e. pulled
to VBAT or to GND. ESW is set to zero if SWI is left open, i.e. floating. ESW is updated synchronously
with ActPos every 1024 s.
Q: Is it possible to swap the logic of the ESW flag?
A: No, it’s not. Actually this is not necessary since the ESW flag must be polled and evaluated by
software anyway. The state of ESW has neither effect on any internal state machine nor on command
processing.
Q: What else is important for the RunInit command?
A: The first target position of RunInit must be different from the current position before sending RunInit
and the second target position must be different from the first one. Otherwise a deadlock situation can
occur. During execution of RunInit only Get… commands should be sent to the device.
Q: Does the second motion of RunInit stop when the ESW flag changes, or does it continue
into the mechanical stop?
A: Neither nor. The SWI input resp. the ESW flag have neither effect on any internal state machine nor
on command processing, i.e. the RunInit command is not influenced by SWI / ESW. The same is true
for the mechanical stop: as there isn’t any internal stall detection the RunInit command can not detect a
mechanical stop. When the mechanical stop is hit the first or second motion of RunInit (or the motion
of any other motion command) will be continued until the internal position counter ActPos has reached
the target position of this motion. This results in the motor bouncing against the mechanical stop and
loosing steps. The intention of the second motion of RunInit is to drive out of the mechanical stop
(reached by the first motion) to the desired reference position at a known distance from the mechanical
stop or to drive slowly against the mechanical stop again to compensate for the bouncing of the first
motion and to come to a standstill as close to the mechanical stop as possible.
Q: Does RunInit reset the position?
A: Yes, it does. After the second motion of RunInit has been finished the internal position counter
ActPos is reset to zero.
相關(guān)PDF資料
PDF描述
TMC222-LI STEPPER MOTOR CONTROLLER, QCC32
TMC222-PI20 STEPPER MOTOR CONTROLLER, PDSO20
TMC22290R2C COLOR SIGNAL ENCODER, PQCC44
TMC22291R2C COLOR SIGNAL ENCODER, PQCC44
TMC2301G8A1 SPECIALTY CONSUMER CIRCUIT, CPGA68
相關(guān)代理商/技術(shù)參數(shù)
參數(shù)描述
TMC223-EVAL 制造商:Trinamic 功能描述:EVAL MODULE FOR TMC223
TMC223-LI 制造商:Trinamic 功能描述: 制造商:Trinamic 功能描述:IC MOTOR CTRLR/DVR I2C 32QFN
TMC223-SI 制造商:Trinamic 功能描述:Bulk
TMC2242 WAF 制造商:Fairchild Semiconductor Corporation 功能描述:
TMC2242A 制造商:FAIRCHILD 制造商全稱:Fairchild Semiconductor 功能描述:Digital Half-Band Interpolating/Decimating Filter 12-bit In/16-bit Out, 60 MHz
主站蜘蛛池模板: 海林市| 桐梓县| 锡林郭勒盟| 阜南县| 缙云县| 绵竹市| 南召县| 邵阳县| 高州市| 法库县| 吕梁市| 江永县| 合肥市| 通海县| 林甸县| 长顺县| 抚顺市| 南通市| 彝良县| 襄垣县| 宁化县| 岑巩县| 镇安县| 临清市| 桐梓县| 武汉市| 来宾市| 邓州市| 商城县| 菏泽市| 巢湖市| 新闻| 武清区| 巩留县| 施秉县| 绵竹市| 屯留县| 韶关市| 富锦市| 尼木县| 普兰店市|