ELECTRICAL CHARACTERISTICS – SYSTEM SEQUENCING AND OPERATING MODES
www.ti.com .............................................................................................................................................................. SLVS663B – MAY 2006 – REVISED APRIL 2008
Over recommended operating conditions (typical values at TJ = 25°C), application circuit as in Figure 3 (unless otherwise noted).
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
QUIESCENT CURRENT
BAT pin current, sleep
IBAT(SLEEP)
Input power not detected, V(BAT) = 4.2 V, Sleep mode set
370
A
mode set
BAT pin current, charge
Charger function enabled by I2C, termination detected, input
IBAT(DONE)
3
A
terminated
power detected and selected
BAT pin current, charge
Charger function disabled by I2C, termination not detected,
IBAT(CHGOFF)
3
A
function OFF
input power detected and selected
Charger function disabled by I2C, termination not detected,
AC or USB pin current,
IINP(CHGOFF)
input power detected and selected. All integrated supplies
200
A
charge function OFF
and drivers OFF, no load at OUT pin.
UNDER-VOLTAGE LOCKOUT
Internal UVLO detection
NO POWER mode set at V(OUT) < VUVLO,
VUVLO
–3%
2.5
3%
V
threshold
V(OUT) decreasing
UVLO detection
VUVLO_HYS
V(OUT) increasing
120
mV
hysteresis
UVLO detection deglitch
tDGL(UVLO)
Falling voltage only
5
ms
time
SYSTEM LOW VOLTAGE THRESHOLD
Minimum system voltage
System voltage V(SYS_IN) decreasing, SLEEP mode set if
VLOW_SYS
0.97
1
1.03
V
detection threshold
V(SYS_IN) < VLOW_SYS
Minimum system voltage
VHYS(LOWSYS)
V(SYS_IN) increasing
50
mV
detection hysteresis
Minimum system voltage
V(SYS_IN) decreasing, valid only for initial power-up, see
tDGL(HOTPLUG) detection hotplug
650
ms
state machine diagram
deglitch time
Minimum system voltage
tDGL(LOWSYS)
V(SYS_IN) decreasing, hotplug deglitch time expired
5
ms
detection deglitch time
THERMAL FAULT
TSHUT
Thermal shutdown
Increasing junction temperature
165
°C
Thermal shudown
THYS(SHUT)
Decreasing junction temperature
30
°C
hysteresis
INTEGRATED SUPPLY POWER FAULT DETECTION
Power good fault
Falling output voltage, applies to all integrated supply outputs.
VPGOOD
84%
90%
96%
detection threshold
Referenced to the programmed output voltage value
Power good fault
Rising output voltage, applies to all integrated supply outputs.
VHYS(PGOOD)
3%
5%
7%
detection hysteresis
Referenced to VPGOOD threshold
HOT RESET FUNCTION
VHRSTON
Low level input voltage
RESET mode set at V(HOT_RESET) < VHRSTON
0.4
V
VHRSTOFF
High level input voltage
HOT reset not active at V(HOT_RESET) > VHRSTOFF
1.3
V
tDGL(HOTRST)
Hot reset input deglitch
5000
s
SYSTEM RESET – OPEN DRAIN OUTPUT RESPWRON
VRSTLO
Low level output voltage
IIL = 10 mA, V(RESPWRON ) < VRSTLO
0
0.3
V
ITRSTPWON
Pullup current source
Internally connected to TRSTPWRON pin
0.9
1
1.2
A
KRESET
Reset timer constant
TRESET = KRESET ° CTRSTPWON
1
ms/nF
SEQUENCING DELAYS
tDLY(D1)
Sequencing delay
See sequencing timing diagram
0.24
ms
tDLY(D1)
Sequencing delay
See sequencing timing diagram
12
ms
Copyright 2006–2008, Texas Instruments Incorporated
7